| Category: | PP Homopolymer , Polypropylene Homopolymer |
| Manufacturer: | Ferro Corporation |
| Trademark: | Ferro PP |
| Fillers: | - |
| Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
| Delivery Terms | FOB, CIF, DAP, DAT, DDP |
| PDF: | zy8Xzi_Ferro-PP-TPP30AJ41BK.pdf |
| PRICE: | Order Products email sales@su-jiao.com |
| Message |
|---|
|
25% minimum post consumer recycle (P.C.R.) Meets/Exceeds Ford Engineering Specification WSS-M4D939-A1. Primary end use is for AC/heater housings. |
| General Information | |
|---|---|
| Filler / Reinforcement |
|
| Additive |
|
| Features |
|
| Appearance |
|
| Forms |
|
| Processing Method |
|
| Physical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Density | 1.14 | g/cm³ | ISO 1183/A |
| Melt Mass-Flow Rate (MFR) (230°C/2.16 kg) | 15 | g/10 min | ISO 1133 |
| Molding Shrinkage | 1.4 | % | ISO 294-4 |
| Mechanical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Tensile Stress (Yield, 23°C) | 28.2 | MPa | ISO 527-2 |
| Flexural Modulus | 3400 | MPa | ISO 178 |
| Impact | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Notched Izod Impact | ISO 180 | ||
| -40°C | 2.1 | kJ/m² | ISO 180 |
| 23°C | 2.7 | kJ/m² | ISO 180 |
| Thermal | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Heat Deflection Temperature | |||
| 0.45 MPa, not annealed | 122 | °C | ISO 75-2/B |
| 1.8 MPa, not annealed | 80.0 | °C | ISO 75-2/A |
| Additional Information |
|---|
| Tensile/Izod Change, ISO 188, 1000 hours, 140°C: +6%/+5% |
| Resin Grade | Manufacturer | Category | Trademark |
|---|---|---|---|
| Maxelast® A9760 | Nantong Polymax Elastomer Technology, Co., Ltd | TPE | Maxelast® |
| Rhelon G2918HU-01 | RheTech, Inc. | Nylon 66 | Rhelon |
| SCHULADUR® A NV12LHI | A. Schulman Inc. | PBT | SCHULADUR® |
| Vipel® K190-BFC-45 | AOC, L.L.C. | Polyester Alloy | Vipel® |
| Sylvin 8707-84 Grey 9533 | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |