Category: | PC , Polycarbonate |
Manufacturer: | SABIC Innovative Plastics |
Trademark: | LEXAN™ |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | zncNvk_LEXAN-FL2000-resin.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
LEXAN FL2000 is a medium flow specialty polycarbonate (PC) resin for structural foam molding, allowing for various weight reductions at 0.24" (6.0mm) wall. This product offers low temperature impact strength and high heat resistance in combination with LEXAN FL2000 resin is available in opaque colors only. |
General Information | |
---|---|
Features |
|
Appearance |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | ASTM D792 | ||
-- 1 | 1.09 | g/cm³ | ASTM D792 |
-- | 1.21 | g/cm³ | ASTM D792 |
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg) | 10 | g/10 min | ASTM D1238 |
Molding Shrinkage - Flow (6.40 mm) | 0.60 - 0.80 | % | Internal method |
Water Absorption | ASTM D570 | ||
24 hr | 0.13 | % | ASTM D570 |
Equilibrium, 23°C | 0.34 | % | ASTM D570 |
Foam - Physical 2 | 10 | % | Internal method |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Foam - Mechanical 3 | 10 | % | Internal method |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Foam - Impact 4 | 10 | % | Internal method |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Foam - Thermal 5 | 10 | % | Internal method |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Foam - Electrical 6 | 20 | % | Internal method |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Foam - Flame Class Minimum Density | 940 | kg/m³ | Internal method |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus (6.40 mm) | 2310 | MPa | ASTM D638 |
Tensile Strength (Yield, 6.35 mm) | 53.8 | MPa | ASTM D638 |
Tensile Elongation (Break, 6.35 mm) | 7.8 | % | ASTM D638 |
Flexural Modulus (6.40 mm) | 1930 | MPa | ASTM D790 |
Flexural Strength (Yield, 6.40 mm) | 75.8 | MPa | ASTM D790 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Unnotched Izod Impact (23°C, 6.40 mm) | 2700 | J/m | ASTM D4812 |
Instrumented Dart Impact | ASTM D3763 | ||
-40°C, Total Energy | 8.13 | J | ASTM D3763 |
-20°C, Total Energy | 67.8 | J | ASTM D3763 |
Dart Drop Impact (23°C) | 122 | J | Internal method |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load | ASTM D648 | ||
0.45 MPa, unannealed, 6.40mm | 138 | °C | ASTM D648 |
1.8 MPa, unannealed, 6.40mm | 127 | °C | ASTM D648 |
CLTE - Flow (-40 to 95°C) | 5.6E-5 | cm/cm/°C | ASTM E831 |
Specific Heat | 1180 | J/kg/°C | ASTM C351 |
RTI Elec | 80.0 | °C | UL 746 |
RTI Imp | 80.0 | °C | UL 746 |
RTI | 80.0 | °C | UL 746 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | > 1.1E+17 | ohms | ASTM D257 |
Volume Resistivity | 3.6E+16 | ohms·cm | ASTM D257 |
Dielectric Constant | ASTM D150 | ||
100 Hz | 2.47 | ASTM D150 | |
1 MHz | 2.68 | ASTM D150 | |
Dissipation Factor | ASTM D150 | ||
100 Hz | 3.7E-3 | ASTM D150 | |
1 MHz | 3.9E-3 | ASTM D150 | |
Arc Resistance 7 | PLC 6 | ASTM D495 | |
Comparative Tracking Index (CTI) | PLC 4 | UL 746 | |
High Amp Arc Ignition (HAI) | PLC 0 | UL 746 | |
High Voltage Arc Tracking Rate (HVTR) | PLC 3 | UL 746 | |
Hot-wire Ignition (HWI) | PLC 0 | UL 746 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | UL 94 | ||
3.91 mm | HB | UL 94 | |
5.99 mm | V-1 | UL 94 | |
Oxygen Index | 28 | % | ASTM D2863 |
Additional Information |
---|
Structural Foam Molding - Blowing Agent, Chemical System: FLC298Structural Foam Molding - Blowing Agent, Physical System: Nitrogen GasStructural Foam Molding - Concentration Range (Blowing Agent): 3 - 5 %Structural Foam Molding - Drying Temperature (Blowing Agent): 104 °CStructural Foam Molding - Drying Temperature (Resin): 121 °CStructural Foam Molding - Drying Time (Blowing Agent): 4 hrsStructural Foam Molding - Drying Time (Resin): 3 - 4 hrsStructural Foam Molding - Drying Time (Resin, Cumulative): 48 hrsStructural Foam Molding - Front Temperature: 293 - 316 °CStructural Foam Molding - Melt Temperature: 291 - 310 °CStructural Foam Molding - Middle Temperature: 293 - 316 °CStructural Foam Molding - Mold Temperature: 71 - 93 °CStructural Foam Molding - Nozzle Temperature: 282 - 304 °CStructural Foam Molding - Rear Temperature: 238 - 260 °CStructural Foam Molding - Recommended Concentration (Blowing Agent): 1.5 % |
Note Message | |
---|---|
1 . | Foam molded |
2 . | 6.4 mm wt reduction |
3 . | 6.4 mm wt reduction |
4 . | 6.4 mm wt reduction |
5 . | 6.4 mm wt reduction |
6 . | 6.4 mm wt reduction |
7 . | Tungsten electrode |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
ALTECH® PA66 D 2030/106 GF30 | ALBIS PLASTIC GmbH | Nylon 66 | ALTECH® PA66 |
DURAFIDE® 6165A4 | Polyplastics Co., Ltd. | PPS | DURAFIDE® |
LIHAN® A705H | Nanjing Lihan Chemical Co., Ltd. | Nylon 66 | LIHAN® |
LNP™ LUBRICOMP™ RX05050 compound | SABIC Innovative Plastics Europe | Nylon 66 | LNP™ LUBRICOMP™ |
Sylvin 9600-95 CLEAR | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |