Category: | PC+ABS , Polycarbonate + ABS |
Manufacturer: | Mitsubishi Engineering-Plastics Corp |
Trademark: | XANTAR® LDS |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | ygRdYi_XANTAR-LDS-3710.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Laser Direct Structuring (LDS)*, Vicat 120°C, Black color only *The compound is intended specifically for the use in the process of manufacturing conducting path designs according to the German application of the patent 101 32 092 of LPKF Laser & Electronics AG. Please address straight to LPKF Laser & Electronics AG (www.LPKF.de). |
General Information | |
---|---|
Appearance |
|
Forms |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.19 | g/cm³ | ISO 1183 |
Melt Volume-Flow Rate (MVR) (260°C/5.0 kg) | 14.0 | cm³/10min | ISO 1133 |
Molding Shrinkage - Flow | 0.60 | % | ISO 294-4 |
Water Absorption (Saturation, 23°C) | 0.60 | % | ISO 62 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 2200 | MPa | ISO 527-2 |
Tensile Stress (Yield) | 50.0 | MPa | ISO 527-2 |
Tensile Strain (Yield) | 4.0 | % | ISO 527-2 |
Nominal Tensile Strain at Break | > 50 | % | ISO 527-2 |
Flexural Modulus | 2250 | MPa | ISO 178 |
Flexural Stress | 80.0 | MPa | ISO 178 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30°C | 60 | kJ/m² | |
23°C | 70 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | ||
-30°C | No Break | ||
23°C | No Break | ||
Notched Izod Impact Strength | ISO 180/4A | ||
-20°C | 40 | kJ/m² | |
23°C | 60 | kJ/m² | |
Multi-Axial Instrumented Impact Energy | |||
-20°C 1 | 4.00 | J | Internal Method |
23°C | 35.0 | J | ISO 6603-2 |
23°C 2 | 10.0 | J | Internal Method |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature (1.8 MPa, Unannealed) | 102 | °C | ISO 75-2/A |
Vicat Softening Temperature | 122 | °C | ISO 306/B50 |
CLTE | ISO 11359-2 | ||
Flow | 7.0E-5 | cm/cm/°C | |
Transverse | 7.0E-5 | cm/cm/°C |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | > 1.0E+15 | ohms | IEC 60093 |
Volume Resistivity | > 1.0E+15 | ohms·cm | IEC 60093 |
Relative Permittivity (1.00 GHz) | 2.80 | IEC 60250 | |
Dissipation Factor (1.00 GHz) | 5.0E-3 | IEC 60250 |
Note Message | |
---|---|
1 . | Part with rib, Based on ISO 6603-2 |
2 . | Part with rib, Based on ISO 6603-2 |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
SCHULAMID® 6 GF 30 H | A. Schulman Europe | Nylon 6 | SCHULAMID® |
TECANAT GF20 | Ensinger Inc. | PC | TECANAT |
Generic Acetal (POM) Copolymer - Aramid Fiber | Generic | Acetal (POM) Copolymer | Generic |
Kemcor MD 6550 | Qenos Pty Ltd | LMDPE | Kemcor |
Kelon® A FR H2 CETG/300-V0 | LATI S.p.A. | Nylon 66 | Kelon® A |