Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | RTP Company |
Trademark: | RTP |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | xiNGMe_RTP-285-TFE-15-SI-2.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Warning: The status of this material is 'Commercial: Limited Issue' The data for this material has not been recently verified. Please contact RTP Company for current information prior to specifying this grade. -Preliminary Product Data per RTP Co.- The value listed as Flammability, UL 94, was tested in accordance with RTP test standards. |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
RoHS Compliance |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.39 | g/cm³ | ASTM D792 |
Molding Shrinkage - Flow (3.18 mm) | 0.10 | % | ASTM D955 |
Water Absorption (23°C, 24 hr) | 0.40 | % | ASTM D570 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness (R-Scale) | 118 | ASTM D785 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 22100 | MPa | ASTM D638 |
Tensile Strength | 207 | MPa | ASTM D638 |
Tensile Elongation (Break) | 2.0 | % | ASTM D638 |
Flexural Modulus | 16500 | MPa | ASTM D790 |
Flexural Strength | 324 | MPa | ASTM D790 |
Compressive Strength | 131 | MPa | ASTM D695 |
Coefficient of Friction (With Metal-Dynamic) | 0.12 | ASTM D1894 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Notched Izod Impact (3.18 mm) | 110 | J/m | ASTM D256 |
Unnotched Izod Impact (3.18 mm) | 910 | J/m | ASTM D4812 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load (1.8 MPa, Unannealed) | 249 | °C | ASTM D648 |
CLTE - Flow | 2.0E-5 | cm/cm/°C | ASTM D696 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity | 10 | ohms·cm | ASTM D257 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | HB | UL 94 |
Additional Information |
---|
Mold Shrinkage, Linear-Flow, ASTM D-955, 0.25in.: 2mil/in.Wear Factor, K, ASTM D-3702: 8E-10in³/min/ft/lb/hrCoefficient of Friction, Dynamic, ASTM D-3702: 0.12The wear factor and dynamic coefficient of friction were both tested on a Falex Model No.6 Wear Testing Machine at 50 FPM, 2000 PV, against C1018 steel of hardness 15-25 Rockwell C, 14-17 micro smoothness. |
Injection | Nominal Value | Unit | |
---|---|---|---|
Drying Temperature | 79.4 | °C | |
Drying Time | 4.0 | hr | |
Suggested Max Moisture | 0.20 | % | |
Suggested Max Regrind | 20 | % | |
Rear Temperature | 274 - 288 | °C | |
Middle Temperature | 274 - 288 | °C | |
Front Temperature | 274 - 288 | °C | |
Mold Temperature | 65.6 - 107 | °C | |
Injection Pressure | 82.7 - 124 | MPa |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
SCHULAMID® 66 GF 35 H | A. Schulman Europe | Nylon 66 | SCHULAMID® |
SUPRAN® PP1330E | SAMBARK | PP, Unspecified | SUPRAN® |
Vipel® K190-RTM-17 | AOC, L.L.C. | Polyester Alloy | Vipel® |
Trilene® RI20HO | Chandra Asri Petrochemical | PP Random Copolymer | Trilene® |
Lytex 4149 | Quantum Composites Inc. | Epoxy | Lytex |