Makrolon® 6485

Category: PC , Polycarbonate
Manufacturer: Covestro - Polycarbonates
Trademark: Makrolon®
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: vOUYiW_Makrolon-6485.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
MVR (300 °C/1.2 kg) 9.0 cm³/10 min; flame retardant; UL 94V-0/1.5 mm and 5VA/3.0 mm; medium viscosity; easy release; injection molding - melt temperature 280 - 320 °C; available in opaque colors only
General Information
Additive
  • Flame Retardant
Features
  • Flame Retardant
  • Good Mold Release
  • Medium Viscosity
RoHS Compliance
  • RoHS Compliant
Appearance
  • Colors Available
  • Opaque
Processing Method
  • Injection Molding
Multi-Point Data
  • Creep Modulus vs. Time (ISO 11403-1)
  • Isochronous Stress vs. Strain (ISO 11403-1)
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Shear Modulus vs. Temperature (ISO 11403-1)
  • Specific Volume vs Temperature (ISO 11403-2)
  • Viscosity vs. Shear Rate (ISO 11403-2)
PhysicalNominal ValueUnitTest Method
Density (23°C)1.20g/cm³ISO 1183
Apparent Density 10.64g/cm³ISO 60
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg)10g/10 minISO 1133
Melt Volume-Flow Rate (MVR) (300°C/1.2 kg)9.00cm³/10minISO 1133
Molding Shrinkage
    Across Flow 0.60 to 0.80%ISO 2577
    Flow 0.60 to 0.80%ISO 2577
    Across Flow : 2.00 mm 20.70%ISO 294-4
    Flow : 2.00 mm 30.65%ISO 294-4
Water Absorption ISO 62
    Saturation, 23°C 0.30%
    Equilibrium, 23°C, 50% RH 0.12%
HardnessNominal ValueUnitTest Method
Ball Indentation Hardness 115MPaISO 2039-1
MechanicalNominal ValueUnitTest Method
Tensile Modulus (23°C)2400MPaISO 527-2/1
Tensile Stress ISO 527-2/50
    Yield, 23°C 66.0MPa
    Break, 23°C 65.0MPa
Tensile Strain ISO 527-2/50
    Yield, 23°C 6.1%
    Break, 23°C 120%
Nominal Tensile Strain at Break (23°C)> 50%ISO 527-2/50
Tensile Creep Modulus ISO 899-1
    1 hr 2200MPa
    1000 hr 1900MPa
Flexural Modulus 4(23°C)2400MPaISO 178
Flexural Stress 5ISO 178
    3.5% Strain, 23°C 74.0MPa
    23°C 98.0MPa
Flexural Strain at Flexural Strength (23°C) 67.1%ISO 178
FlammabilityNominal ValueUnitTest Method
Application of Flame from Small Burner - Method K and F (2.00 mm) K1, F1DIN 53438-1, -3
Burning Rate - US-FMVSS (> 1.00 mm) passedISO 3795
Flash Ignition Temperature 460°CASTM D1929
Glow Wire Test EDF HN60 E.02
    1.50 mm 750°C
    3.00 mm 750°C
Needle Flame Test IEC 60695-11-5
    Method F : 1.50 mm 2.0min
    Method F : 2.00 mm 2.0min
    Method F : 3.00 mm 2.0min
    Method K : 1.50 mm 2.0min
    Method K : 2.00 mm 2.0min
    Method K : 3.00 mm 2.0min
Self Ignition Temperature 540°CASTM D1929
Additional InformationNominal ValueTest Method
Electrolytical Corrosion (23°C) A1IEC 60426
ISO Shortname ISO 7391-PC,MFR,(,,)-09-9
ImpactNominal ValueUnitTest Method
Charpy Notched Impact Strength 7ISO 7391
    -30°C, Complete Break 14kJ/m²
    23°C, Partial Break 70kJ/m²
Charpy Unnotched Impact Strength ISO 179/1eU
    -60°C No Break
    -30°C No Break
    23°C No Break
Notched Izod Impact Strength 8ISO 7391
    -30°C, Complete Break 12kJ/m²
    23°C, Partial Break 65kJ/m²
Multi-Axial Instrumented Impact Energy ISO 6603-2
    -30°C 55.0J
    23°C 50.0J
Multi-Axial Instrumented Impact Peak Force ISO 6603-2
    -30°C 6000N
    23°C 5200N
ThermalNominal ValueUnitTest Method
Heat Deflection Temperature
    0.45 MPa, Unannealed 136°CISO 75-2/B
    1.8 MPa, Unannealed 124°CISO 75-2/A
Glass Transition Temperature 9142°CISO 11357-2
Vicat Softening Temperature
    -- 144°CISO 306/B50
    -- 145°CISO 306/B120
Ball Pressure Test (136°C)PassIEC 60695-10-2
CLTE ISO 11359-2
    Flow : 23 to 55°C 6.5E-5cm/cm/°C
    Transverse : 23 to 55°C 6.5E-5cm/cm/°C
Thermal Conductivity 10(23°C)0.20W/m/KISO 8302
RTI Elec (1.50 mm)125°CUL 746
RTI Imp (1.50 mm)115°CUL 746
RTI Str (1.50 mm)125°CUL 746
ElectricalNominal ValueUnitTest Method
Surface Resistivity 1.0E+16ohmsIEC 60093
Volume Resistivity (23°C)1.0E+16ohms·cmIEC 60093
Electric Strength (23°C, 1.00 mm)34kV/mmIEC 60243-1
Relative Permittivity IEC 60250
    23°C, 100 Hz 3.10
    23°C, 1 MHz 3.00
Dissipation Factor IEC 60250
    23°C, 100 Hz 8.0E-4
    23°C, 1 MHz 9.0E-3
Comparative Tracking Index IEC 60112
    Solution A 225V
    Solution B 125V
FlammabilityNominal ValueUnitTest Method
Flame Rating UL 94
    0.750 mm V-1
    1.50 mm V-0
    3.00 mm 5VA
Glow Wire Flammability Index IEC 60695-2-12
    0.750 mm 960°C
    1.50 mm 960°C
    3.00 mm 960°C
Glow Wire Ignition Temperature IEC 60695-2-13
    0.750 mm 875°C
    1.50 mm 875°C
    3.00 mm 875°C
Oxygen Index 1136%ISO 4589-2
Note Message
1 .Pellets
2 .60x60x2 mm, 500 bar
3 .60x60x2 mm, 500 bar
4 .2.0 mm/min
5 .2.0 mm/min
6 .2 mm/min
7 .Based on ISO 179-1eA, 3 mm
8 .Based on ISO 180-A, 3 mm
9 .10°C/min
10 .Cross-flow
11 .Procedure A
Resin Grade Manufacturer Category Trademark
CP PRYME® Nylon 66 NN333HSL BK-P Chase Plastics Services Inc. Nylon 66 CP PRYME® Nylon 66
Fibremod™ GB306SAF Borealis AG PP, Unspecified Fibremod™
GAPEX® FPP30GQ23HB Ferro Corporation PP, Unspecified GAPEX®
MAGNUM™ 357 HP Trinseo ABS MAGNUM™
ULTEM™ D9065 resin SABIC Innovative Plastics PEI ULTEM™