Category: | XLPE , Crosslinked Polyethylene |
Manufacturer: | Polylink Polymers (India) Ltd. |
Trademark: | Polylink Power Cable |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | ukeQA0_Polylink-Power-Cable-PP-408-401.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
A silane grafted crosslinkable polyethylene compound, curable by exposure to moisture, for insulation of power cables and possessing excellent extrudability at high out put rate. PP 408 is based on a high molecular weight polymer and has melt index in the range of 0.5 to 0.8. It has especially developed for low voltage cable insulation and for sheathing purpose. DESCRIPTION : This compound utilizes the system for cross - linking of polyethylene developed by DOW Corning and known as Sioplas. It is a two component system comprising a silylated ethylene polymer known as the graft copolymer PP 408 , and a master batch PP 401 containing a cross - linking catalyst. The two materials normally used in the ratio of 95 parts graft to 5 parts catalyst master batch. |
General Information | |
---|---|
Features |
|
Uses |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 0.925 | g/cm³ | ASTM D1505 |
Melt Mass-Flow Rate (MFR) (190°C/2.16 kg) | 0.50 | g/10 min | ASTM D1238 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Stress (Break) | 18.0 | MPa | IEC 60811 |
Tensile Strain (Break) | 550 | % | IEC 60811 |
Aging | Nominal Value | Unit | Test Method |
---|---|---|---|
Change in Tensile Strength in Air (135°C, 168 hr) | 10 | % | IEC 60811 |
Change in Tensile Strain at Break in Air (135°C, 168 hr) | 15 | % | IEC 60811 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Thermoset 1 | IEC 60811 | ||
Elongation Under Load : 200°C | 100 | % | IEC 60811 |
Permanent Elongation after Cooling : 200°C | 5.0 | % | IEC 60811 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Power factor (23°C) 2 | 4.00E-4 | IEC 250 | |
Volume Resistivity (20°C) | 2.4E+16 | ohms·cm | IEC 60502 |
Dielectric Strength | 25 | kV/mm | IEC 60243-1 |
Dielectric Constant | 2.30 | IEC 60250 |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Cylinder Zone 1 Temp. | 160 | °C | |
Cylinder Zone 2 Temp. | 170 | °C | |
Cylinder Zone 3 Temp. | 180 | °C | |
Cylinder Zone 4 Temp. | 190 | °C | |
Cylinder Zone 5 Temp. | 200 | °C | |
Die Temperature | 210 | °C |
Extrusion instructions |
---|
Screw water temperature : 60 to70°CScreens : 30,100,30(mesh apertures per linear inch)L/D Ratio: 20Compression: 3:0:1 |
Note Message | |
---|---|
1 . | 15 min, 0.2 N/mm² |
2 . | 50 Hz |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Arylmax® K7500WC30 | Polymics, Ltd. | PAEK | Arylmax® |
Hanwha Total PP BI392 | HANWHA TOTAL PETROCHEMICALS Co., Ltd. | PP, Unspecified | Hanwha Total PP |
KEBALLOY® C43 | BARLOG plastics GmbH | PC+ABS | KEBALLOY® |
Petroquim PP PH 0952 | Petroquim S.A. | PP Homopolymer | Petroquim PP |
Sylvin 86027-75 Clear | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |