Category: | TP, Unspecified , Thermoplastic |
Manufacturer: | Melos GmbH |
Trademark: | Mecoline |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | uG87bO_Mecoline-S-TP-1006-F.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Halogen-free, low smoke, thermoplastic, highly flame retardant compound for the sheathing of low and medium voltage cables in General Installation applications. |
General Information | |
---|---|
Additive |
|
Features |
|
Uses |
|
Agency Ratings |
|
RoHS Compliance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.56 | g/cm³ | ISO 1183/A |
Melt Mass-Flow Rate (MFR) (160°C/21.6 kg) | 5.0 | g/10 min | ISO 1133 |
pH | > 4.5 | DIN VDE 0472 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Hot Pressure Test - penetration 6h at 90°C | 27 | % | DIN VDE 0472 |
Temperature Index | 280 | °C | ASTM D2863 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Conductivity | < 10.0 | µS/mm |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Head Temperature | 140 to 160 | °C | |
Extruder Screw L/D Ratio | 20.0:1.0 to 25.0:1.0 | ||
Extruder Screw Compression Ratio | 1.0:1.2 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Shore Hardness (Shore D) | 50 | ISO 7619 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Stress | 10.3 | MPa | IEC 811-1-1 |
Tensile Strain (Break) | 180 | % | IEC 811-1-1 |
Aging | Nominal Value | Unit | Test Method |
---|---|---|---|
Change in Tensile Strength in Air | IEC 811-1-2 | ||
100°C, 240 hr | -9.7 | % | |
120°C, 168 hr | 1.9 | % | |
Change in Tensile Strain at Break in Air | IEC 811-1-2 | ||
100°C, 240 hr | 11 | % | |
120°C, 168 hr | 11 | % |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Brittleness Temperature | -20.0 | °C | ASTM D746 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity 1 | > 1.0E+12 | ohms | DIN VDE 0303 |
Volume Resistivity 2 | > 1.0E+12 | ohms·cm | DIN VDE 0303 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Oxygen Index | 45 | % | ASTM D2863 |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Cylinder Zone 1 Temp. | 110 to 130 | °C | |
Cylinder Zone 2 Temp. | 115 to 135 | °C | |
Cylinder Zone 3 Temp. | 120 to 140 | °C | |
Cylinder Zone 4 Temp. | 125 to 145 | °C | |
Cylinder Zone 5 Temp. | 130 to 150 | °C | |
Adapter Temperature | 135 to 155 | °C | |
Die Temperature | 150 to 170 | °C |
Note Message | |
---|---|
1 . | 16h at 20°C, 500V |
2 . | 16h at 20°C, 500V |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
PRL PC-UV4 | Polymer Resources Ltd. | PC | PRL |
RAMCLEAN™ 101 | Polyram Ram-On Industries | TP, Unspecified | RAMCLEAN™ |
SLOVAMID® 6 GB 30 TS | Plastcom | Nylon 6 | SLOVAMID® 6 |
DuraStar™ MN610 | Eastman Chemical Company | Polyester, TP | DuraStar™ |
Eltex® Superstress™ CAP602S2 | INEOS Olefins & Polymers Europe | HDPE Copolymer | Eltex® |