Category: | Polyolefin, Unspecified , Polyolefin |
Manufacturer: | Borealis AG |
Trademark: | Casico™ |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | pQIf4p_Casico-FR4807.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Casico FR4807 is a thermoplastic, low smoke zero halogen (LSZH) flame retardant, UV stabilised, natural jacketing compound combining with excellent extrusion properties. It is based on the novel technology, Casico, containing inorganic filler and a novel char-forming additive which confer flame retardancy with very limited smoke generation. It can be used in areas sensitive to smoke or corrosive and toxic combustion products. For most cable constructions, Casico FR4807 has sufficient flame retardancy to satisfy single wire vertical burning tests. Casico FR4807 meets the applicable requirements below using sound commercial extrusion practice and testing procedures:
|
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Uses |
|
Agency Ratings |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density 1 | 1.15 | g/cm³ | ISO 1183 |
Melt Mass-Flow Rate (MFR) (190°C/2.16 kg) | 1.0 | g/10 min | ISO 1133 |
Water Absorption (70°C) 2 | 0.400 | mg/cm² | IEC 60811-1-3 |
Thermal | Nominal Value | Test Method | |
---|---|---|---|
Cold Bend (-40°C) 3 | Pass | IEC 60811-1-4 | |
Cold Impact (-40°C) 4 | Pass | IEC 60811-1-4 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
NBS Smoke Density | ASTM E662 | ||
-- 5 | 6.0 | min | |
-- 6 | 46.0 | ||
-- 7 | 20.0 | min | |
-- 8 | 54.0 |
Additional Information | Nominal Value | Unit | Test Method |
---|---|---|---|
Breakdown Duration 9 | Pass | IEC 60227-2/2.3 | |
Breakdown Voltage 10 | 32000 | V | ISO 6722 |
Cone Calorimeter | ISO 5660 | ||
-- 11 | 1.80 | kg/m³ | |
Average Heat Release 12 | 193 | kW/m² | |
CO 13 | 0.260 | kg/m³ | |
Heat Combustion 14 | 28.0 | ||
Ignition time 15 | 2.2 | min | |
Max Heat Release 16 | 335 | kW/m² | |
Smoke Obscuration 17 | 531 | ||
Corrosion - of Combustion Fumes 18 | 1.80 | µS/cm | IEC 60754-2 |
Pressure Test (80°C) 19 | 17 | % | IEC 60811-3-1 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Shore Hardness 20(Shore D, 15 sec) | 31 | ISO 868 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Stress (Yield) | 11.5 | MPa | IEC 60811-1-1 |
Tensile Strain 21(Break) | 700 | % | IEC 60811-1-1 |
Flexural Modulus 22 | 100 | MPa | ISO 178 |
Aging | Nominal Value | Unit | Test Method |
---|---|---|---|
Change in Tensile Stress | |||
-- 23 | > -80 | % | ISO 1817 |
100°C, 240 hr 24 | > -80 | % | IEC 60811-1-2 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity 25 | 6.0E+15 | ohms·cm | IEC 60093 |
Electric Strength | > 20 | kV/mm | IEC 60243-1 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Oxygen Index 26 | 34 | % |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Cylinder Zone 1 Temp. | 110 | °C | |
Cylinder Zone 2 Temp. | 140 | °C | |
Cylinder Zone 3 Temp. | 160 | °C | |
Cylinder Zone 4 Temp. | 170 | °C | |
Die Temperature | 170 | °C |
Note Message | |
---|---|
1 . | Compound, ISO 1872-2 |
2 . | 14 days, Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
3 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
4 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
5 . | Time to Dmax, (76x76x0.7 mm plaque), Flaming mode |
6 . | Optical smoke density Dmax, (76x76x0.7 mm plaque), Flaming mode |
7 . | Time to Dmax, (76x76x0.7 mm plaque), Non-flaming mode |
8 . | Optical smoke density Dmax, (76x76x0.7 mm plaque), Non-flaming mode |
9 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
10 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
11 . | heat flux 35 kW/m2, 3 mm plaque |
12 . | heat flux 35 kW/m2, 3 mm plaque |
13 . | heat flux 35 kW/m2, 3 mm plaque |
14 . | heat flux 35 kW/m2, 3 mm plaque, MJ/dm3 |
15 . | heat flux 35 kW/m2, 3 mm plaque |
16 . | heat flux 35 kW/m2, 3 mm plaque |
17 . | heat flux 35 kW/m2, 3 mm plaque, m2/dm3 |
18 . | Compound, 5.3 |
19 . | at high temperature, 4 hrs, Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
20 . | Compound |
21 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
22 . | Compound |
23 . | After UV ageing, Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
24 . | Cable (0.7 mm insulation over 1.5 mm² solid Cu) |
25 . | Compound |
26 . | Compound |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
SLOVALEN® PC 13 T 30 | Plastcom | PP, Unspecified | SLOVALEN® |
DURACON® M270-45 | Polyplastics Co., Ltd. | Acetal (POM) Copolymer | DURACON® |
Geon™ HTX E1502 | PolyOne Corporation | PVC Alloy | Geon™ HTX |
ISOPAK® 640 | Great Eastern Resins Industrial Co Ltd (GRECO) | PC+ABS | ISOPAK® |
ISOTHANE® 3070DU-W | Great Eastern Resins Industrial Co., Ltd. (GRECO) | TPU-Polyether | ISOTHANE® |