| Category: | Nylon 6 , Polyamide 6 |
| Manufacturer: | A. Schulman Europe |
| Trademark: | SCHULAMID® |
| Fillers: | - |
| Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
| Delivery Terms | FOB, CIF, DAP, DAT, DDP |
| PDF: | mrbidi_SCHULAMID-6-GF-30-HI-FR-4.pdf |
| PRICE: | Order Products email sales@su-jiao.com |
| Message |
|---|
| 30% glass fibre reinforced and impact modified PA 6; flame retardant containing halogens without PBDE |
| General Information | |
|---|---|
| Filler / Reinforcement |
|
| Additive |
|
| Features |
|
| Processing Method |
|
| Physical | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Density | 1.59 | -- | g/cm³ | ISO 1183/A |
| Mechanical | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Tensile Modulus | 11000 | 8500 | MPa | ISO 527-2/1A/1 |
| Tensile Stress (Break) | 150 | 104 | MPa | ISO 527-2/1A/5 |
| Tensile Strain (Break) | 2.5 | 4.0 | % | ISO 527-2/1A/5 |
| Impact | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/1eA | |||
| -30°C | 8.5 | -- | kJ/m² | |
| 23°C | 10 | 12 | kJ/m² | |
| Charpy Unnotched Impact Strength | ISO 179/1eU | |||
| -30°C | 54 | -- | kJ/m² | |
| 23°C | 60 | 65 | kJ/m² |
| Thermal | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Heat Deflection Temperature | ||||
| 0.45 MPa, Unannealed | 216 | -- | °C | ISO 75-2/Bf |
| 1.8 MPa, Unannealed | 207 | -- | °C | ISO 75-2/Af |
| Vicat Softening Temperature | ||||
| -- | 211 | -- | °C | ISO 306/A120 |
| -- | 203 | -- | °C | ISO 306/B50 |
| Electrical | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Surface Resistivity | > 1.0E+15 | -- | ohms | IEC 60093 |
| Volume Resistivity | > 1.0E+13 | -- | ohms·cm | IEC 60093 |
| Comparative Tracking Index | 225 | -- | V | IEC 60112 |
| Flammability | Dry | Conditioned | Unit | Test Method |
|---|---|---|---|---|
| Flammability Classification | IEC 60695-11-10, -20 | |||
| 0.800 mm | V-0 | -- | ||
| 1.60 mm | V-2 | -- | ||
| Glow Wire Flammability Index | IEC 60695-2-12 | |||
| 0.750 mm | 960 | -- | °C | |
| 1.50 mm | 960 | -- | °C | |
| 3.00 mm | 960 | -- | °C | |
| Glow Wire Ignition Temperature | IEC 60695-2-13 | |||
| 0.750 mm | 800 | -- | °C | |
| 1.50 mm | 800 | -- | °C | |
| 3.00 mm | 800 | -- | °C | |
| Oxygen Index | 34 | -- | % | ISO 4589-2 |
| Resin Grade | Manufacturer | Category | Trademark |
|---|---|---|---|
| Axiall PVC 6652 | Axiall Corporation | PVC, Flexible | Axiall PVC |
| Durethan® B 35 F 000000 | LANXESS Corporation | Nylon 6 | Durethan® |
| Indothene HD 46GP009UV | Reliance Industries Limited | HDPE | Indothene HD |
| PERCOM® KAH16FR | A. Schulman Europe | PP, Unspecified | PERCOM® |
| Thermec N™ 4314R45HY | Technical Polymers, LLC | PPA | Thermec N™ |