Category: | PVC, Unspecified , Polyvinyl Chloride |
Manufacturer: | AlphaGary |
Trademark: | SMOKEGUARD™ III |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | meWgX1_SMOKEGUARD-III-1096-NATURAL.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
A LEAD FREE, LOW SMOKE, HIGHLY FLAME RETARDED, SMOKEGUARD™ COMPOUND FOR PLENUM CABLE APPLICATIONS. |
General Information | |
---|---|
Features |
|
Uses |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.64 - 1.68 | g/cm³ | ASTM D792 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Durometer Hardness | ASTM D2240 | ||
Shaw D | 68 - 74 | ASTM D2240 | |
Shaw D, 15 seconds | 54 - 60 | ASTM D2240 |
Elastomers | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Strength | ASTM D412 | ||
0.381 mm | 17.2 | MPa | ASTM D412 |
1.91 mm | 15.2 | MPa | ASTM D412 |
Tensile Elongation | ASTM D412 | ||
Fracture, 1.91mm | 200 | % | ASTM D412 |
Fracture, 0.381mm | 190 | % | ASTM D412 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Brittleness Temperature | -1.00 | °C | ASTM D746 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Dielectric Constant (23°C, 100 MHz) | 3.50 | ASTM D150 | |
Dissipation Factor (23°C, 100 MHz) | 0.012 | ASTM D150 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Oxygen Index (3.18 mm) | 62 | % | ASTM D2863 |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Cylinder Zone 1 Temp. | 149 | °C | |
Cylinder Zone 2 Temp. | 154 | °C | |
Cylinder Zone 3 Temp. | 163 | °C | |
Cylinder Zone 4 Temp. | 168 | °C | |
Cylinder Zone 5 Temp. | 168 | °C | |
Adapter Temperature | 166 | °C | |
Melt Temperature | 177 - 185 | °C | |
Die Temperature | 171 | °C | |
Extruder Screw Compression Ratio | 3.0:1.0 |
Extrusion instructions |
---|
Melt temperature is critical, at temperatures above 370 degrees F foaming may occur. It may be necessary to adjust barrel temp to attain the desired melt temperature Material should be dried prior to use |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Maxelast® C4909 | Nantong Polymax Elastomer Technology, Co., Ltd | TPE | Maxelast® |
Sarlink® TPV 2487 | Teknor Apex Company | TPV | Sarlink® TPV |
NORYL GTX™ APS430 resin | SABIC Innovative Plastics Asia Pacific | PPS+PPE | NORYL GTX™ |
Laticonther 62 GR/50 | LATI S.p.A. | Nylon 6 | Laticonther |
LubriOne™ PS-30CF/15T BK701 | PolyOne Corporation | PBT | LubriOne™ |