Santoprene™ 8281-35MED

Category: TPV , Thermoplastic Vulcanizate
Manufacturer: ExxonMobil Chemical
Trademark: Santoprene™
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: kiGwUg_Santoprene-8281-35MED.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
It is a soft, colorable, special non-hygroscopic thermoplastic vulcanized elastomer (TPV) in the thermoplastic elastomer (TPE) series. It applies to the field of health care. This brand of Shanduping TPV is a shear rate dependent product that can be processed on conventional thermoplastic injection molding equipment. This is a polyolefin-based material that can be recycled in the production process.
General Information
Features
  • Low extract
  • Radiation disinfection
  • Recyclable materials
  • Good coloring
  • High pressure heating resistance
  • Good chemical resistance
  • Oil resistance
  • Biocompatibility
  • Low or no water absorption
  • Disinfect with steam
Uses
  • Medical/nursing supplies
Agency Ratings
  • USP Class VI
RoHS Compliance
  • RoHS compliance
Appearance
  • Natural color
Forms
  • Particle
Processing Method
  • Multiple injection molding
  • Injection molding
PhysicalNominal ValueUnitTest Method
Specific Gravity
    -- 0.908g/cm³ASTM D792
    -- 0.910g/cm³ISO 1183
HardnessNominal ValueUnitTest Method
Durometer Hardness (Shaw A, 15 seconds, 23°C, 2.00mm)39ISO 868
ElastomersNominal ValueUnitTest Method
Tensile Stress - Across Flow (100% Strain, 23°C)0.900MPaASTM D412, ISO 37
Tensile Strength - Across Flow (Break, 23°C)2.60MPaASTM D412, ISO 37
Tensile Elongation - Across Flow (Break, 23°C)330%ASTM D412, ISO 37
Tear Strength - Across Flow
    23°C 19.00kN/mASTM D624
    100°C 24.00kN/mASTM D624
    23°C 39.0kN/mISO 34-1
    100°C 44.0kN/mISO 34-1
Compression Set
    23°C, 168 hr 513%ASTM D395B
    23°C, 168 hr 613%ISO 815
Additional Information
如果适用,这是基于扇形浇口注塑成型的平板测试结果。拉伸强度、伸长率和拉伸应力沿垂直流动方向测定 - ISO 1 型,ASTM die C。25% 形变时的永久压缩变形。从埃克森美孚欧洲分支机构直接购买的所有产品都符合 REACH 法规。 对于埃克森 美孚未进口至欧洲的产品,用户应自行评估其是否满足 REACH 法规。
Legal statement
未经埃克森美孚化工书面允许,这种产品包括其产品名称,不得在任何医疗应用领域予以使用或有关详细的产品监管信息,请联系客户服务。
InjectionNominal ValueUnit
Suggested Max Moisture 0.080%
Suggested Max Regrind 20%
Rear Temperature 177 - 191°C
Middle Temperature 179 - 193°C
Front Temperature 185 - 199°C
Nozzle Temperature 185 - 210°C
Processing (Melt) Temp 143 - 216°C
Mold Temperature 23.9 - 51.7°C
Injection Rate Fast
Back Pressure 0.345 - 0.689MPa
Screw Speed 100 - 200rpm
Clamp Tonnage 4.1 - 6.9kN/cm²
Cushion 3.18 - 6.35mm
Screw L/D Ratio 16.0:1.0 to 20.0:1.0
Screw Compression Ratio 2.0:1.0 to 2.5:1.0
Vent Depth 0.025mm
Injection instructions
Santoprene TPV与乙缩醛和PVC不相容。
Note Message
1 .C mould
2 .C mould
3 .Method B, right-angle specimen (cut)
4 .Method B, right-angle specimen (cut)
5 .Type 1
6 .Type a
Resin Grade Manufacturer Category Trademark
Starflam PZ0052E Eurostar Engineering Plastics Nylon 6 Starflam
Vythene™ VYT/11X-50 RV1 CLEAR TL 0002 AlphaGary PVC+PUR Vythene™
WELLAMID Nylon 6000 CF 10 HWCP CP-Polymer-Technik GmbH & Co. KG Nylon 6 WELLAMID Nylon
Caltex PP MT42FC GS Caltex PP, Unspecified Caltex PP
LNP™ VERTON™ E9007E compound SABIC Innovative Plastics PEI LNP™ VERTON™