Zytel® FR50 NC010A

Category: Nylon 66 , NYLON RESIN
Manufacturer: DuPont Performance Polymers
Trademark: Zytel®
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: hrEvxF_Zytel-FR50-NC010A.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
25% Glass Reinforced, Flame Retardant, Polyamide 66
General Information
Filler / Reinforcement
  • Glass Fiber, 25% Filler by Weight
Additive
  • Mold Release
Agency Ratings
  • UL Unspecified Rating
Forms
  • Pellets
Processing Method
  • Injection Molding
Multi-Point Data
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Shear Stress vs. Shear Rate (ISO 11403-1)
  • Specific Volume vs Temperature (ISO 11403-2)
  • Viscosity vs. Shear Rate (ISO 11403-2)
Part Marking Code (ISO 11469)
  • >PA66-GF25FR(17)<
Resin ID (ISO 1043)
  • PA66-GF25FR(17)
PhysicalDryConditionedUnitTest Method
Density 1.60--g/cm³ISO 1183
Molding Shrinkage ISO 294-4
     Across Flow 0.80--%
     Flow 0.30--%
Water Absorption (Equilibrium, 23°C, 2.00 mm, 50% RH)0.70--%ISO 62
MechanicalDryConditionedUnitTest Method
Tensile Modulus 106007500MPaISO 527-2
Tensile Stress (Break)170--MPaISO 527-2
Tensile Strain (Break)2.5--%ISO 527-2
Flexural Modulus 9450--MPaISO 178
ImpactDryConditionedUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
     -40°C 11--kJ/m²
     23°C 11--kJ/m²
Charpy Unnotched Impact Strength (23°C)40--kJ/m²ISO 179/1eU
ThermalDryConditionedUnitTest Method
Heat Deflection Temperature
     0.45 MPa, Unannealed 256--°CISO 75-2/B
     1.8 MPa, Unannealed 246--°CISO 75-2/A
Glass Transition Temperature 180.0--°CISO 11357-2
Melting Temperature 2261--°CISO 11357-3
CLTE ISO 11359-2
     Flow 1.9E-5--cm/cm/°C
     Transverse 1.0E-4--cm/cm/°C
ElectricalDryConditionedUnitTest Method
Volume Resistivity > 1.0E+15--ohms·cmIEC 60093
Electric Strength 38--kV/mmIEC 60243-1
Dissipation Factor IEC 60250
     100 Hz 0.018--
     1 MHz 0.018--
Comparative Tracking Index (CTI) PLC 2--UL 746
Comparative Tracking Index 285--VIEC 60112
FlammabilityDryConditionedUnitTest Method
Flammability Classification IEC 60695-11-10, -20
     0.350 mm V-0--
     1.50 mm V-0 5VA--
Fill AnalysisDryConditionedUnitTest Method
Melt Density 1.40--g/cm³
Specific Heat Capacity of Melt 1660--J/kg/°C
Thermal Conductivity of Melt 0.22--W/m/K
Additional InformationDryConditionedUnitTest Method
Emission of Organic Compounds 4.70--µgC/gVDA 277
Odor 4.5--VDA 270
Note Message
1 .10°C/min
2 .10°C/min
Resin Grade Manufacturer Category Trademark
Premier LH01019 - BP Premier Polymers, LLC. LLDPE Premier
MOSTEN NB 218 UNIPETROL RPA PP Homopolymer MOSTEN
INSTRUC PBTGF10 Infinity LTL Engineered Compounds PBT INSTRUC
MAJ'ECO DP374HGM AD majoris PP, Unspecified MAJ'ECO
Hifax CB 1160 G1 BLACK LyondellBasell Industries PP Copolymer Hifax