Plenco 04311 (Compression)

Category: Phenolic , Phenolic
Manufacturer: Plastics Engineering Co.
Trademark: Plenco
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: hi1Csn_Plenco-04311-Compression-.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
PLENCO 04311 is a heat resistant, mineral filled phenolic molding compound offering excellent processability, mechanical strength, and improved cold powder pourability characteristics. UL recognized under component file E40654. 04311 is available in black.
General Information
Filler / Reinforcement
  • Mineral filler
Features
  • Workability, good
  • Good strength
  • Heat resistance, high
UL File Number
  • E40654
Appearance
  • Black
Forms
  • Particles
Processing Method
  • Compression molding
PhysicalNominal ValueUnitTest Method
Specific Gravity 1.48g/cm³ASTM D792
Apparent Density 0.68g/cm³ASTM D1895
Molding Shrinkage - Flow 0.33%ASTM D955
Water Absorption (24 hr)0.29%ASTM D570
HardnessNominal ValueUnitTest Method
Rockwell Hardness (E-Scale)83ASTM D785
MechanicalNominal ValueUnitTest Method
Tensile Modulus 8790MPaASTM D638
Tensile Strength 54.0MPaASTM D638
Tensile Elongation (Break)0.60%ASTM D638
Flexural Modulus 9180MPaASTM D790
Flexural Strength 78.3MPaASTM D790
Compressive Strength 186MPaASTM D695
ImpactNominal ValueUnitTest Method
Charpy Notched Impact Strength 19.9J/mASTM D256
Notched Izod Impact 17J/mASTM D256
ThermalNominal ValueUnitTest Method
Deflection Temperature Under Load (1.8 MPa, Unannealed)186°CASTM D648
Continuous Use Temperature 203°CASTM D794
CLTE - Flow 8.2E-5cm/cm/°CASTM E831
Thermal Conductivity (100°C)0.50W/m/KASTM C177
ElectricalNominal ValueUnitTest Method
Volume Resistivity 6.9E+12ohms·cmASTM D257
Dielectric Strength 115kV/mmASTM D149
Dielectric Constant (1 MHz)4.70ASTM D150
Dissipation Factor (1 MHz)0.037ASTM D150
Arc Resistance 166secASTM D495
Comparative Tracking Index (CTI) 175VUL 746
FlammabilityNominal ValueUnitTest Method
Flame Rating (1.50 mm)V-1UL 94
Oxygen Index 27%ASTM D2863
Additional Information
The value listed as Thermal Conductivity, ASTM C177 was tested according to the ASTM E1461 standard.The value listed as Mold Shrink, Linear-Flow, ASTM D955 was tested according to the ASTM D6289 standard.The value listed as Comparative Tracking Index, UL 746 was tested according to ASTM D3638.Post Shrinkage, ASTM D6289, 72hr, 120°C: 0.17%Heat Resistance, ASTM D794: 203°CDrop Ball Impact, PLENCO Method: 85 J/m
InjectionNominal ValueUnit
Drying Temperature 90.0°C
Drying Time 0.50hr
Mold Temperature 165 - 182°C
Back Pressure 0.300MPa
Screw Speed < 60rpm
Injection instructions
Mold Close Time: 3-8 sec
Note Message
1 .Method A (short time)
Resin Grade Manufacturer Category Trademark
RTP 283E RTP Company Nylon, Unspecified RTP
TECHNYL® A 218 V30 NATURAL Solvay Engineering Plastics Nylon 66 TECHNYL® A
Andur M-8700 AP (1,4BD) Anderson Development Company PUR-MDI Andur
PETLIN LD C225Y PETLIN (MALAYSIA) SDN BHD LDPE PETLIN
Sylvin 8225-95LMWUV Black Sylvin Technologies Incorporated PVC, Unspecified Sylvin