Category: | LCP , Liquid Crystal Polymer |
Manufacturer: | BARLOG plastics GmbH |
Trademark: | KEBAFLOW® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | hDRYIM_KEBAFLOW-LCP-HF130.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
LCP, 30% glass fiber reinforced, HDT ~300°C |
General Information | |
---|---|
Filler / Reinforcement |
|
Resin ID (ISO 1043) |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.62 | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | ||
Across Flow | 0.46 | % | |
Flow | 0.16 | % | |
Water Absorption (Saturation, 23°C) | 0.040 | % | Internal Method |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 14000 | MPa | ISO 527-2 |
Tensile Stress (Break) | 136 | MPa | ISO 527-2 |
Tensile Strain (Break) | 1.5 | % | ISO 527-2 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature (1.8 MPa, Unannealed) | 305 | °C | ISO 75-2/A |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | 1.0E+15 | ohms | IEC 60093 |
Volume Resistivity | 1.0E+15 | ohms·cm | IEC 60093 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flammability Classification 1(0.800 mm) | V-0 | IEC 60695-11-10, -20 |
Note Message | |
---|---|
1 . | UL Registered |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Rilsamid® AMVO TLD | Arkema | Nylon 12 | Rilsamid® |
Starflam PZ0042E | Eurostar Engineering Plastics | Nylon 6 | Starflam |
Grilon® BR 40 | EMS-GRIVORY | Nylon 6 | Grilon® |
Indothene HD HD55EF010 | Reliance Industries Limited | HDPE | Indothene HD |
Ingeo™ 6361D | NatureWorks® LLC | PLA | Ingeo™ |