| Category: | PMMA+PVC , Acrylic (PMMA) + PVC |
| Manufacturer: | SEKISUI Polymer Innovations, LLC |
| Trademark: | KYDEX® |
| Fillers: | - |
| Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
| Delivery Terms | FOB, CIF, DAP, DAT, DDP |
| PDF: | gRyKmF_KYDEX-FST-CTL.pdf |
| PRICE: | Order Products email sales@su-jiao.com |
| Message |
|---|
|
KYDEX® FST CTL is a translucent thermoplastic sheet specifically formulated to meet all Boeing and Airbus toxicity requirements for aircraft interior components. KYDEX® FST CTL meets the flammability, smoke development, and heat release requirements set forth in Federal Aviation Regulations (FAR) 25.853 paragraphs (a) and (d) as well as the toxicity requirements for Airbus (ABD0031) and Boeing (BSS7239). Its excellent thermoforming characteristics make it an ideal material for three-dimensional components where transparent design elements are desirable. |
| General Information | |
|---|---|
| Features |
|
| Uses |
|
| Agency Ratings |
|
| Appearance |
|
| Forms |
|
| Physical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Specific Gravity | 1.34 | g/cm³ | ASTM D792 |
| Mechanical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Tensile Modulus (3.18 mm) | 2390 | MPa | ASTM D638 |
| Tensile Strength (3.18 mm) | 74.5 | MPa | ASTM D638 |
| Flexural Modulus (3.18 mm) | 2450 | MPa | ASTM D790 |
| Flexural Strength (3.18 mm) | 101 | MPa | ASTM D790 |
| Thermal | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Deflection Temperature Under Load (1.8 MPa, Annealed, 3.18 mm) | 125 | °C | ASTM D648 |
| CLTE - Flow | 5.4E-5 | cm/cm/°C | ASTM E831 |
| Flammability | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Toxic gas emission 1 | Pass | ||
| Flammability | |||
| NBS Smoke Density 2 | FAR 25.853(d) | ||
| OSU Heat Release, Peak 3 | kW/m² | FAR 25.853(d) | |
| OSU Heat Release, Total 4 | kW·min/m² | FAR 25.853(d) | |
| Vertical Burn, 12 Second | Pass | FAR 25.853(a) | |
| Vertical Burn, 60 Second | Pass | FAR 25.853(a) |
| Additional Information |
|---|
| Note: Pre-drying of KYDEX® FST CTL is required prior to thermoforming in order to remove moisture from the sheet.Disclaimer: KYDEX® FST CTL is for interior use only. Color may exhibit lot-to-lot variation. |
| Note Message | |
|---|---|
| 1 . | ABD0031, BSS 7239 |
| 2 . | Part V |
| 3 . | Part IV |
| 4 . | Part IV |
| Resin Grade | Manufacturer | Category | Trademark |
|---|---|---|---|
| Polytech & Net XP 9200EN | Polytech & Net Gmbh | mLLDPE | Polytech & Net |
| Sylvin 8815-80 Grey 9491 | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |
| FHR Polypropylene 23M2A | Flint Hills Resources, LP | PP Random Copolymer | FHR Polypropylene |
| Lucalen A 3110 M Q 244 | LyondellBasell Industries | EAA | Lucalen |
| POLYfill PPC T16040 | Polykemi AB | PP Copolymer | POLYfill |