Category: | PC , Polycarbonate Resin |
Manufacturer: | Trinseo |
Trademark: | CALIBRE™ |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | VK279b_CALIBRE-2061-15.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
CALIBRE™ 2061-15 resin is suitable for steam and ethylene oxide sterilization required by the health care industry. CALIBRE 2061-15 provides exceptional clarity, heat resistance, impact strength, processability, and has low contamination levels. CALIBRE 2061-15 resin is compliant with ISO 10993 (Biological Evaluation of Medical Devices) and is suitable for use in approved medical applications. This product contains mold release. Main Characteristics:
Applications:
|
General Information | |
---|---|
Additive |
|
Features |
|
Uses |
|
Agency Ratings |
|
Forms |
|
Processing Method |
|
Multi-Point Data |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | |||
-- | 1.20 | g/cm³ | ASTM D792, ISO 1183/A |
-- | 1200 | kg/m³ | ISO 1183 1 |
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg) | 15 | g/10 min | ASTM D1238, ISO 1133 |
Melt volume-flow rate (300°C/1.2 kg) | 12.0 | cm³/10min | ISO 1133 2 |
Molding Shrinkage - Flow | 0.50 to 0.70 | % | ASTM D955, ISO 294-4 |
Water Absorption | ASTM D570, ISO 62 | ||
23°C, 24 hr | 0.15 | % | |
Equilibrium, 23°C, 50% RH | 0.32 | % |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness | ASTM D785 | ||
M-Scale | 73 | ||
R-Scale | 118 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | |||
-- 3 | 2210 | MPa | ASTM D638 |
-- | 2300 | MPa | ISO 527-2/50, ISO 527-2 4 |
Tensile Strength | |||
Yield 5 | 62.1 | MPa | ASTM D638 |
Yield | 62.0 | MPa | ISO 527-2/50 |
Yield | 60.0 | MPa | ISO 527-2 6 |
Break 7 | 68.3 | MPa | ASTM D638 |
Break | 68.0 | MPa | ISO 527-2/50 |
Tensile Elongation | |||
Yield 8 | 6.0 | % | ASTM D638 |
Yield | 6.0 | % | ISO 527-2/50, ISO 527-2 9 |
Break 10 | 150 | % | ASTM D638 |
Break | 150 | % | ISO 527-2/50 |
Nominal strain at break | > 50 | % | ISO 527-2 11 |
Flexural Modulus | |||
-- 12 | 2410 | MPa | ASTM D790 |
-- 13 | 2400 | MPa | ISO 178 |
Flexural Strength | |||
-- 14 | 96.5 | MPa | ASTM D790 |
-- 15 | 98.0 | MPa | ISO 178 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength | |||
23°C | 25 | kJ/m² | ISO 179/1eA |
-30°C | 12.0 | kJ/m² | ISO 179/1eA 16 |
23°C | 80.0 | kJ/m² | ISO 179/1eA 17 |
Charpy impact strength | ISO 179/1eU 18 | ||
-30°C | No Break | ||
23°C | No Break | ||
Notched Izod Impact | |||
23°C | 750 | J/m | ASTM D256 |
23°C | 74 | kJ/m² | ISO 180/A |
Unnotched Izod Impact (23°C) | No Break | ASTM D256, ISO 180 | |
Instrumented Dart Impact 19(23°C, Total Energy) | 81.3 | J | ASTM D3763 |
Tensile Impact Strength | 378 | kJ/m² | ASTM D1822 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load | |||
0.45 MPa, Annealed | 139 | °C | ASTM D648, ISO 75-2/B |
0.45 MPa | 144 | °C | ISO 75-2 20 |
1.8 MPa, Unannealed | 122 | °C | ASTM D648 |
1.8 MPa, Unannealed | 120 | °C | ISO 75-2/A |
1.8 MPa, Annealed | 136 | °C | ASTM D648, ISO 75-2/A |
1.8 MPa | 130 | °C | ISO 75-2 21 |
Vicat Softening Temperature | |||
-- | 148 | °C | ASTM D1525 22 |
-- | 143 | °C | ISO 306/B50 |
50°C/h, B (50N) | 148 | °C | ISO 306 23 |
CLTE - Flow | |||
-40 to 82°C | 6.8E-5 | cm/cm/°C | ASTM D696 |
-- | 7.0E-5 | cm/cm/°C | ISO 11359-2 24 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity | |||
-- | 2.0E+17 | ohms·cm | ASTM D257 |
-- | > 1.0E+13 | ohms·m | IEC 60093 25 |
Dielectric Strength | 17 | kV/mm | ASTM D149, IEC 60243-1 |
Dielectric Constant | |||
60 Hz | 3.00 | ASTM D150 | |
1 MHz | 3.00 | ASTM D150, IEC 60250 26 | |
100 Hz | 3.00 | IEC 60250 27 | |
Dissipation Factor | |||
50 Hz | 1.0E-3 | ASTM D150 | |
1 MHz | 2.0E-3 | ASTM D150, IEC 60250 28 | |
100 Hz | 1.0E-3 | IEC 60250 29 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | UL 94 | ||
1.50 mm 30 | HB | ||
3.00 mm | HB | ||
0.750 mm | V-2 | ||
1.50 mm | V-2 | ||
Oxygen index | 26 | % | ISO 4589-2 31 |
Optical | Nominal Value | Unit | Test Method |
---|---|---|---|
Refractive Index | 1.586 | ASTM D542, ISO 489 | |
Transmittance 32 | 89.0 | % | ASTM D1003 |
Haze 33 | 1.0 | % | ASTM D1003 |
Note Message | |
---|---|
1 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
2 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
3 . | 50 mm/min |
4 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
5 . | 50 mm/min |
6 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
7 . | 50 mm/min |
8 . | 50 mm/min |
9 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
10 . | 50 mm/min |
11 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
12 . | Method I (3 point load), 2.0 mm/min |
13 . | 2.0 mm/min |
14 . | Method I (3 point load), 2.0 mm/min |
15 . | 2.0 mm/min |
16 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
17 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
18 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
19 . | 3.39 m/sec |
20 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
21 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
22 . | Rate A (50°C/h), Loading 2 (50 N) |
23 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
24 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
25 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
26 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
27 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
28 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
29 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
30 . | This rating not intended to reflect hazards presented by this or any other material under actual fire conditions. |
31 . | Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
32 . | Measured at 3.2mm thickness on un-colored resin. |
33 . | Measured at 3.2mm thickness on un-colored resin. |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
RTP 900 GF-120 | RTP Company | PSU | RTP |
Ferro PP TPP40AJ35BK | Ferro Corporation | PP Homopolymer | Ferro PP |
LUVOCOM® 1105-0895/BL | Lehmann & Voss & Co. | PEEK | LUVOCOM® |
Sylvin 4225-95 Natural | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |
Sylvin 9077-75 Blue 8358 | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |