Category: | Vinyl Ester , Vinyl Ester |
Manufacturer: | AOC, L.L.C. |
Trademark: | Vipel® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | SB5T7w_VipelF010H2O00.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
F010-H2O-00 Coating System for Potable Water POTABLE WATER NSF/ANSI 61 Certified Vipel F010-H2O-00 is certified to NSF/ANSI 61 for use in commercial and domestic potable water systems as a protective barrier material. If fabricators follow the ingredients and process instructions listed on page 3, they do not need to perform additional testing to manufacture a NSF/ANSI 61 compliant coating. BENEFITS Suitable for Sodium Hypochlorite Containment The formulation of Vipel F010-H2O-00 is also appropriate and suitable for sodium hypochlorite (chlorine bleach) containment. Sodium hypochlorite is a widely accepted water purification chemical that is very aggressive to most metals and many polymeric materials. The use of coatings that are not formulated for sodium hypochlorite containment will reduced the service life of the equipment. |
General Information | |
---|---|
Features |
|
Uses |
|
Agency Ratings |
|
Forms |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Styrene Content | 39 | % |
Additional Information | Nominal Value | Unit | Test Method |
---|---|---|---|
Critical Strain Energy | 100 | J/m² | ASTM E399 |
Gel to Peak | 10.0 | min | |
Peak Exotherm | 180 | °C | |
Stress Intensity Factor | 0.600 | ASTM E399 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Barcol Hardness | 39 | ASTM D2583 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 3170 | MPa | ASTM D638 |
Tensile Strength | 88.3 | MPa | ASTM D638 |
Tensile Elongation (Break) | 6.2 | % | ASTM D638 |
Flexural Modulus | 3450 | MPa | ASTM D790 |
Flexural Strength | 152 | MPa | ASTM D790 |
Compressive Strength | 121 | MPa | ASTM D695 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load (1.8 MPa, Unannealed) | 120 | °C | ASTM D648 |
Glass Transition Temperature | 130 | °C | DIN 53445 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | > 1.0E+13 | ohms | DIN 53482 |
Volume Resistivity 1 | > 1.0E+16 | ohms·cm | DIN 53482 |
Dielectric Strength (0.700 mm) | 120 | kV/mm | DIN 53481 |
Dielectric Constant | DIN 53483 | ||
60 Hz 2 | 3.40 | DIN 53483 | |
60 Hz 3 | 3.50 | DIN 53483 | |
1 kHz 4 | 3.40 | DIN 53483 | |
1 kHz 5 | 3.50 | DIN 53483 | |
1 MHz 6 | 3.30 | DIN 53483 | |
1 MHz 7 | 3.40 | DIN 53483 | |
Dissipation Factor | DIN 53483 | ||
60 Hz 8 | 2.5E-3 | DIN 53483 | |
60 Hz 9 | 3.7E-3 | DIN 53483 | |
1 kHz 10 | 2.2E-3 | DIN 53483 | |
1 kHz 11 | 3.3E-3 | DIN 53483 | |
1 MHz 12 | 1.6E-3 | DIN 53483 | |
1 MHz 13 | 2.3E-3 | DIN 53483 |
Uncured Properties | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.05 | g/cm³ | |
Viscosity (25°C, Brookfield RVT) | 0.30 | Pa·s | |
Gel Time (25°C) | 20 | min |
Note Message | |
---|---|
1 . | Dry |
2 . | Dry |
3 . | after 24 hrs in drinking water |
4 . | Dry |
5 . | after 24 hrs in drinking water |
6 . | Dry |
7 . | after 24 hrs in drinking water |
8 . | Dry |
9 . | after 24 hrs in drinking water |
10 . | Dry |
11 . | after 24 hrs in drinking water |
12 . | Dry |
13 . | after 24 hrs in drinking water |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
NOVAPOLY 0225UV | NOVA Polymers, Inc. | PC Alloy | NOVAPOLY |
CERTENE™ PHB-07 | Muehlstein | PP, HMS | CERTENE™ |
Dugdale PVC Flexible Injection Molding - Shore A 58 Compound | Dugdale Plc | PVC, Flexible | Dugdale PVC |
Petrothene® NA217000 | LyondellBasell Industries | LDPE | Petrothene® |
Polifil® PP CAS-40 | The Plastics Group | PP, Unspecified | Polifil® PP |