Category: | Fluorelastomer , Fluoroelastomer |
Manufacturer: | Greene, Tweed & Co. |
Trademark: | Greene FKM |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | S5PECD_Greene-FKM-731.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Greene FKM 731 is a Fluoroelastomer product. It is available in North America. |
General Information | |
---|---|
Appearance |
|
Forms |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.84 | g/cm³ | ASTM D297 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness (M-Scale) | 78 | ASTM D785 | |
Durometer Hardness (Shore A) | 75 | ASTM D2240 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Coefficient of Friction 1 | ASTM D1894 | ||
vs. Itself - Dynamic | 0.50 | ||
vs. Itself - Static | 1.3 |
Elastomers | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Stress | ASTM D412 | ||
50% Strain | 2.86 | MPa | |
100% Strain | 6.76 | MPa | |
Tensile Strength (Break) | 15.2 | MPa | ASTM D412 |
Tensile Elongation (Break) | 190 | % | ASTM D412 |
Tear Strength 2 | 34.1 | kN/m | ASTM D624 |
Compression Set | |||
149°C, 70 hr | 6.0 | % | ASTM D395 |
150°C, 22 hr | 6.0 | % | ASTM D395 |
175°C, 70 hr 3 | 16 | % | ASTM D395 |
175°C, 70 hr 4 | 24 | % | ASTM D395 |
175°C, 166 hr | 24 | % | ASTM D395 |
200°C, 22 hr | 9.0 | % | ASTM D395 |
200°C, 22 hr 5 | 10 | % | ASTM D395B |
200°C, 70 hr | 11 | % | ASTM D395 |
Aging | Nominal Value | Unit | Test Method |
---|---|---|---|
Change in Tensile Strength in Air | ASTM D573 | ||
150°C, 70 hr | -12 | % | |
276°C, 70 hr | -30 | % | |
Change in Ultimate Elongation in Air | ASTM D573 | ||
150°C, 70 hr | 6.0 | % | |
276°C, 70 hr | 16 | % | |
Change in Durometer Hardness in Air | ASTM D573 | ||
150°C, 70 hr | 6.0 | ||
276°C, 70 hr | 6.0 | ||
Change in Tensile Strength | ASTM D471 | ||
100°C, 168 hr, in Actuator Oil | -15 | % | |
100°C, 168 hr, in SAE 10 Oil | -27 | % | |
Change in Ultimate Elongation | ASTM D471 | ||
100°C, 168 hr, in Actuator Oil | 1.2 | % | |
100°C, 168 hr, in SAE 10 Oil | -9.6 | % | |
Change in Durometer Hardness | ASTM D471 | ||
100°C, 168 hr, in Actuator Oil | -4.0 | ||
100°C, 168 hr, in SAE 10 Oil | -6.0 | ||
Change in Volume | ASTM D471 | ||
100°C, 168 hr, in Actuator Oil | 3.4 | % | |
100°C, 168 hr, in SAE 10 OIL | 4.4 | % |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
CLTE - Flow | 2.1E-4 | cm/cm/°C | ASTM E228 |
Note Message | |
---|---|
1 . | Method C |
2 . | Die B |
3 . | In AMS 3021 Fluid |
4 . | In AMS 3021 After 18 Hrs Soak |
5 . | In air |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Zenite® 5145L | Celanese Corporation | LCP | Zenite® |
Generic PC+Polyester - Glass Fiber | Generic | PC+Polyester | Generic |
ISPLEN® PB 300 A3M | REPSOL | PP Impact Copolymer | ISPLEN® |
Edistir® N 3380 | Versalis S.p.A. | PS (GPPS) | Edistir® |
LEXAN™ 123 resin | SABIC Innovative Plastics | PC | LEXAN™ |