Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | AKRO-PLASTIC GmbH |
Trademark: | AKROMID® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | RTe4rP_AKROMID-B3-GF-30-1-natural-2464-.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
AKROMID® B3 GF 30 1 natural (2464) is a 30% glass fibre reinforced, heat stabilised polyamide 6 with high rigidity and strength and light inherent color, UL listed. Applications are mainly components in mechanical engineering and in the automotive industry |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Uses |
|
Appearance |
|
Resin ID (ISO 1043) |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density (23°C) | 1.36 | -- | g/cm³ | ISO 1183 |
Spiral Flow | 66.0 | -- | cm | Internal Method |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 0.80 | -- | % | |
Flow | 0.10 | -- | % | |
Water Absorption (Saturation, 23°C) | 6.3 to 6.9 | -- | % | ISO 62 |
Humidity Absorption - 62% RH (70°C) | 2.1 to 2.3 | -- | % | ISO 1110 |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Temperature Index | IEC 216 | |||
50% Loss of Tensile Strength, 20000 hr | 130 to 150 | -- | °C | |
50% Loss of Tensile Strength, 5000 hr | 160 to 175 | -- | °C |
Additional Information | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Reinforcement Content | 30 | -- | % | ISO 1172 |
Hardness | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Ball Indentation Hardness (H 961/30) | 230 | -- | MPa | ISO 2039-1 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 10300 | 6200 | MPa | ISO 527-2/1 |
Tensile Stress (Break) | 185 | 110 | MPa | ISO 527-2/5 |
Tensile Strain (Break) | 3.0 | 5.5 | % | ISO 527-2/5 |
Flexural Modulus 1 | 8500 | -- | MPa | ISO 178 |
Flexural Stress 2 | 270 | -- | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | 12 | -- | kJ/m² | |
23°C | 13 | 18 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | 85 | -- | kJ/m² | |
23°C | 95 | 110 | kJ/m² |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 220 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 210 | -- | °C | ISO 75-2/A |
8.0 MPa, Unannealed | 150 | -- | °C | ISO 75-2/C |
Melting Temperature 3 | 220 | -- | °C | DIN EN 11357-1 |
CLTE | ISO 11359-2 | |||
Flow : 23 to 80°C | 1.6E-5 | -- | cm/cm/°C | |
Transverse : 23 to 80°C | 9.5E-5 | -- | cm/cm/°C |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | 1.0E+12 | 1.0E+10 | ohms | IEC 60093 |
Volume Resistivity | 1.0E+13 | 1.0E+10 | ohms·cm | IEC 60093 |
Comparative Tracking Index (Solution A) | 600 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Burning Rate 4(1.00 mm) | < 100 | -- | mm/min | FMVSS 302 |
Flame Rating (0.800 mm) | HB | -- | UL 94 | |
Glow Wire Flammability Index (1.60 mm) | 650 | -- | °C | IEC 60695-2-12 |
Note Message | |
---|---|
1 . | 2.0 mm/min |
2 . | 2.0 mm/min |
3 . | 10 K/min, DSC |
4 . | >1 mm |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
RTP ESD A 280A | RTP Company | Nylon 6 | RTP |
CoolPoly® E3603 | Celanese Corporation | PPA | CoolPoly® |
Kingfa JH720 G20 | Kingfa | PC Alloy | Kingfa |
Huafon JF-S-AH8045 | Huafon Group Co., Ltd. | PUR, Unspecified | Huafon |
Lifocork® UV 701021-2 | ELASTO | TPE | Lifocork® |