Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | BASF Corporation |
Trademark: | Ultramid® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | OVNuFi_Ultramid-A3UG5.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Without halogenes and red phosphorus a flame retarded glass fiber reinforced injection moulding grade; light in colour with outstanding mechanical and electrical properties. |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Agency Ratings |
|
RoHS Compliance |
|
Forms |
|
Processing Method |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.39 | -- | g/cm³ | ISO 1183 |
Apparent Density | 0.70 | -- | g/cm³ | |
Melt Volume-Flow Rate (MVR) (275°C/5.0 kg) | 25.0 | -- | cm³/10min | ISO 1133 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 1.2 | -- | % | |
Flow | 0.40 | -- | % | |
Water Absorption | ISO 62 | |||
Saturation, 23°C | 4.0 to 4.6 | -- | % | |
Equilibrium, 23°C, 50% RH | 1.1 to 1.5 | -- | % | |
Viscosity Number (96% H2SO4 (Sulphuric Acid)) | 165 | -- | cm³/g | ISO 307 |
Mold Shrinkage - model-housing (1.50 mm) | 0.40 | -- | % |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Temperature Index - at 50% loss of tensile strength | IEC 60216 | |||
-- 1 | 155 | -- | °C | |
-- 2 | 130 | -- | °C |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Fire Performance - UL94+HAI+HWI 3 | > 750.0 | -- | µm | UL 746C |
French Railway Standard - Fire and smoke classification 4 | I3/F2 | -- | NF F16-101 | |
Smoke Density - Ds max. (20 min), 25kW/m² (2.00 mm) | 250 | -- | ISO 5659-2 | |
Smoke Toxicity 5 | 0.380 | -- |
Additional Information | Dry | Conditioned | ||
---|---|---|---|---|
Polymer Abbreviation | PA66-GF25 FR | -- |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 9500 | 6100 | MPa | ISO 527-2 |
Tensile Stress (Break) | 145 | 90.0 | MPa | ISO 527-2 |
Tensile Strain (Break) | 3.0 | 5.0 | % | ISO 527-2 |
Flexural Modulus | 9500 | 6100 | MPa | ISO 178 |
Flexural Stress | 230 | 160 | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength (23°C) | 7.5 | 9.0 | kJ/m² | ISO 179/1eA |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | 63 | -- | kJ/m² | |
23°C | 65 | 65 | kJ/m² |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 260 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 245 | -- | °C | ISO 75-2/A |
Melting Temperature | 260 | -- | °C | ISO 11357-3 |
RTI Elec (1.50 mm) | 120 | -- | °C | UL 746 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | -- | 1.0E+15 | ohms | IEC 60093 |
Volume Resistivity | 1.0E+16 | 1.0E+13 | ohms·cm | IEC 60093 |
Relative Permittivity (1 MHz) | 3.80 | 4.60 | IEC 60250 | |
Dissipation Factor (1 MHz) | 0.017 | 0.10 | IEC 60250 | |
Comparative Tracking Index (Solution A) | 600 | -- | V | IEC 60112 |
High Amp Arc Ignition (HAI) (> 0.750 mm) | PLC 0 | -- | UL 746 | |
Hot-wire Ignition (HWI) 6(> 0.750 mm) | PLC 0 | -- | UL 746 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating | UL 94 | |||
> 0.750 mm | V-0 | -- | ||
1.60 mm | V-0 | -- | ||
3.20 mm | V-0 | -- | ||
Glow Wire Flammability Index (0.750 mm) | 960 | -- | °C | IEC 60695-2-12 |
Glow Wire Ignition Temperature (> 2.00 mm) | 775 | -- | °C | IEC 60695-2-13 |
Oxygen Index | 32 | -- | % | ISO 4589-2 |
Injection | Dry | Unit | |
---|---|---|---|
Processing (Melt) Temp | 280 to 300 | °C | |
Mold Temperature | 80.0 to 90.0 | °C |
Note Message | |
---|---|
1 . | 5000 h |
2 . | 20000 h |
3 . | For Electrical Insulation/Barrier with close proximity (<0.8 mm) to unisulated live parts according to UL 746C |
4 . | Limited validity period |
5 . | NF X70-100-1/-2 |
6 . | ASTM D3874-88 |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Rhelon G1033U-01 | RheTech, Inc. | Nylon 6 | Rhelon |
Sarlink® TPE EE-2272N | Teknor Apex Company | TPE | Sarlink® TPE |
Tecoform® PO20 NL IL | Eurotec Engineering Plastics | Acetal (POM) Copolymer | Tecoform® |
ACCUTECH™ CP0437M30L | ACLO Compounders Inc. | PP Copolymer | ACCUTECH™ |
Dryflex® 502850S | ELASTO | SEBS | Dryflex® |