Mecoline IS RDX 1221 F

Category: TP, Unspecified , Thermoplastic
Manufacturer: Melos GmbH
Trademark: Mecoline
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: NaD6oY_Mecoline-IS-RDX-1221-F.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
This compound is an ideal choice for the insulation of heat-resistant wires and cables for general applications in railway systems, nuclear power stations, engine compartments and other areas.
General Information
Additive
  • Flame Retardant
Features
  • Flame Retardant
  • Good Flexibility
  • Halogen Free
  • High Heat Resistance
  • Irradiation Crosslinkable
  • Low Smoke Emission
  • Low Temperature Flexibility
Uses
  • Automotive Applications
  • Cable Jacketing
  • Insulation
  • Nuclear Power Applications
  • Wire & Cable Applications
RoHS Compliance
  • RoHS Compliant
Forms
  • Pellets
Processing Method
  • Extrusion
PhysicalNominal ValueUnitTest Method
Density 1.41g/cm³ISO 1183/A
Melt Mass-Flow Rate (MFR) (160°C/10.0 kg)7.0g/10 minISO 1133
pH 4.5IEC 60754-2
ThermalNominal ValueUnitTest Method
Hot Set 1IEC 540
    Elongation under load 20%
    Residual elongation 10%
Temperature Index 225°CASTM D2863
ElectricalNominal ValueUnitTest Method
Conductivity 2.00µS/mm
FlammabilityNominal ValueUnitTest Method
Halogen Content 0%IEC 754-1
Toxicity 2.00EN 50305
ExtrusionNominal ValueUnit
Head Temperature 160 to 170°C
Extruder Screw L/D Ratio >24.0:1.0
HardnessNominal ValueUnitTest Method
Shore Hardness (Shore D)49ISO 7619
MechanicalNominal ValueUnitTest Method
Tensile Stress IEC 811-1-1
    -- 217.0MPa
    -- 3> 8.00MPa
Tensile Strain IEC 811-1-1
    Break 4350%
    Break 5> 600%
AgingNominal ValueUnitTest Method
Change in Tensile Strength in Air (158°C, 168 hr)10%IEC 811-1-2
Change in Tensile Strain at Break in Air (158°C, 168 hr)-2.0%IEC 811-1-2
ElectricalNominal ValueUnitTest Method
Volume Resistivity 4.0E+12ohms·cmASTM D257
Dielectric Strength 25kV/mmASTM D149
Dielectric Constant (20°C, 50 Hz)5.00ASTM D150
Dissipation Factor (20°C, 50 Hz)0.025ASTM D150
FlammabilityNominal ValueUnitTest Method
Oxygen Index 32%ASTM D2863
ExtrusionNominal ValueUnit
Drying Temperature 50.0°C
Drying Time 3.0hr
Cylinder Zone 1 Temp. 130 to 140°C
Cylinder Zone 2 Temp. 150 to 160°C
Cylinder Zone 3 Temp. 160 to 170°C
Cylinder Zone 4 Temp. 160 to 170°C
Cylinder Zone 5 Temp. 160 to 170°C
Adapter Temperature 160 to 170°C
Die Temperature 160 to 170°C
Note Message
1 .at 200°C/15min/0.2 MPa
2 .After crosslinking
3 .Before crosslinking
4 .After crosslinking
5 .Before crosslinking
Resin Grade Manufacturer Category Trademark
G-Lex B52A003 Gas Authority of India Limited HDPE G-Lex
LARIPUR® LPR 5520 COIM S.p.A. TPU-Polyester LARIPUR®
PROXESS 1806S3 Braskem LLDPE PROXESS
StarFlex® 7092-1003 Star Thermoplastic Alloys & Rubbers, Inc. TPE StarFlex®
Durethan® BKV 50 H EF DUS022 900116 LANXESS GmbH Nylon 6 Durethan®