Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.45 | g/cm³ | ISO 1183 |
Molding Shrinkage 1 | ISO 294-4 | ||
Across Flow : 2.00 mm | 0.75 to 1.0 | % | |
Flow : 2.00 mm | 0.30 to 0.60 | % | |
Water Absorption (23°C, 24 hr) | 0.26 | % | ISO 62 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | ISO 527-2/1 | ||
23°C | 9800 | MPa | |
60°C | 8100 | MPa | |
90°C | 4900 | MPa | |
120°C | 3900 | MPa | |
150°C | 3100 | MPa | |
Tensile Stress | ISO 527-2/5 | ||
Break, 23°C | 145 | MPa | |
Break, 60°C | 110 | MPa | |
Break, 90°C | 70.0 | MPa | |
Break, 120°C | 55.0 | MPa | |
Break, 150°C | 45.0 | MPa | |
Tensile Strain | ISO 527-2/5 | ||
Break, 23°C | 2.2 | % | |
Break, 60°C | 2.4 | % | |
Break, 90°C | 3.9 | % | |
Break, 120°C | 4.0 | % | |
Break, 150°C | 4.3 | % |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength (23°C) | 10 | kJ/m² | ISO 179/1eA |
Charpy Unnotched Impact Strength (23°C) | 100 | kJ/m² | ISO 179/1eU |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature | |||
0.45 MPa, Unannealed | 260 | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 250 | °C | ISO 75-2/A |
Continuous Use Temperature 2 | 125 | °C | |
Vicat Softening Temperature | 240 | °C | ISO 306/B50 |
CLTE - Flow (30 to 100°C) | 8.0E-6 | cm/cm/°C | ISO 11359-2 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Comparative Tracking Index (Solution A) | 600 | V | IEC 60112 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | UL 94 | ||
0.750 mm | V-0 | ||
1.50 mm | V-0 | ||
3.00 mm | V-0 | ||
Glow Wire Flammability Index | IEC 60695-2-12 | ||
1.00 mm | 960 | °C | |
2.00 mm | 960 | °C | |
Glow Wire Ignition Temperature | IEC 60695-2-13 | ||
1.00 mm | 725 | °C | |
2.00 mm | 775 | °C | |
Oxygen Index | 27 | % | ASTM D2863 |
Additional Information | Nominal Value | ||
---|---|---|---|
Dimensional Stability | 54.0 |
Injection | Nominal Value | Unit | |
---|---|---|---|
Drying Temperature | 90.0 to 100 | °C | |
Drying Time | 3.0 | hr | |
Suggested Max Regrind | 15 | % | |
Processing (Melt) Temp | 270 to 290 | °C | |
Mold Temperature | 70.0 to 100 | °C | |
Injection Rate | Moderate |
Note Message | |
---|---|
1 . | 60 MPa |
2 . | 20,000 hr |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Matrixx FP62E33 | The Matrixx Group, Inc. | Nylon 6 | Matrixx |
SIBUR PP H552 IM/2 | SIBUR, LLC | PP Homopolymer | SIBUR PP |
STABAMID® 27 FE 5 | Solvay Polyamide & Intermediates | Nylon 66 | STABAMID® |
VENYL UE020 | AD majoris | Nylon 66 | VENYL |
ISPLEN® PM 275 AW | REPSOL | PP Copolymer | ISPLEN® |