Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | DSM Engineering Plastics |
Trademark: | Akulon® Ultraflow |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | MCTxsG_Akulon-Ultraflow-K-FHG7-A.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Akulon® Ultraflow K-FHG7 /A is a Polyamide 6 (Nylon 6) material filled with 35% glass fiber. It is available in Europe. Important attributes of Akulon® Ultraflow K-FHG7 /A are:
|
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Forms |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.40 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 1.0 | -- | % | |
Flow | 0.30 | -- | % | |
Water Absorption | ISO 62 | |||
Saturation, 23°C | 5.6 | -- | % | |
Equilibrium, 23°C, 50% RH | 1.7 | -- | % |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 11000 | 7000 | MPa | ISO 527-2 |
Tensile Stress (Break) | 185 | 125 | MPa | ISO 527-2 |
Tensile Strain (Break) | 3.3 | 6.5 | % | ISO 527-2 |
Flexural Modulus | 10000 | -- | MPa | ISO 178 |
Flexural Stress | 255 | -- | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | 12 | 12 | kJ/m² | |
23°C | 15 | 23 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | 70 | 70 | kJ/m² | |
23°C | 95 | 100 | kJ/m² |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 220 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 200 | -- | °C | ISO 75-2/A |
Melting Temperature 1 | 220 | -- | °C | ISO 11357-3 |
CLTE | ISO 11359-2 | |||
Flow | 1.5E-5 | -- | cm/cm/°C | |
Transverse | 6.0E-5 | -- | cm/cm/°C |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | -- | > 1.0E+15 | ohms | IEC 60093 |
Volume Resistivity | > 1.0E+15 | > 1.0E+15 | ohms·cm | IEC 60093 |
Relative Permittivity | IEC 60250 | |||
100 Hz | 3.50 | 14.0 | ||
1 MHz | 3.30 | 4.40 | ||
Dissipation Factor | IEC 60250 | |||
100 Hz | 5.0E-3 | 0.30 | ||
1 MHz | 0.015 | 0.12 | ||
Comparative Tracking Index | 500 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flammability Classification (1.50 mm) | HB | -- | IEC 60695-11-10, -20 |
Injection | Dry | Unit | |
---|---|---|---|
Drying Temperature | 80.0 | °C | |
Drying Time | 4.0 to 8.0 | hr | |
Rear Temperature | 230 to 250 | °C | |
Middle Temperature | 230 to 260 | °C | |
Front Temperature | 230 to 260 | °C | |
Nozzle Temperature | 250 to 280 | °C | |
Processing (Melt) Temp | 245 to 270 | °C | |
Mold Temperature | 40.0 to 80.0 | °C | |
Injection Rate | Moderate-Fast | ||
Back Pressure | 3.00 to 10.0 | MPa | |
Screw Compression Ratio | 2.5:1.0 |
Note Message | |
---|---|
1 . | 10°C/min |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
RTP 900 P-1700 | RTP Company | PSU | RTP |
ELASTEL™ NPCV-HO7-LF | HELLENIC CABLES S.A. | PVC+NBR | ELASTEL™ |
Infino LH-1070W | SAMSUNG SDI CO., LTD. | PC | Infino |
MAJORIS GT300 - 8229 | AD majoris | PP, Unspecified | MAJORIS |
NORYL™ 731 resin | SABIC Innovative Plastics | PPE+PS | NORYL™ |