Promyde® B30 P2 G30

Category: Nylon 6 , Polyamide 6
Manufacturer: NUREL, S.A.
Trademark: Promyde®
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: MB4ZGG_Promyde-B30-P2-G30.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
Promyde B30 P2 G30 is a Polyamide 6 UL certified injection moulding grade with 30% glass fibre and heat stabilized.

CHARACTERISTICS
Promyde B30 P2 G30 is distinguished by high mechanical strength, hardness, rigidity, thermo stability (melting point 220°C), and resistance to hot lubricants and water. Parts made from Promyde B30 P2 G30 have particularly high dimensional stability and creep strength.

APPLICATIONS
Promyde B30 P2 G30 is used in a wide range of applications where a combination of mechanical properties and thermal resistance is needed.

Glass-fibre reinforced grades are suitable for housings, supports, industrial articles and electrical insulating parts.
General Information
Filler / Reinforcement
  • Glass fiber reinforced material, 30% filler by weight
Additive
  • heat stabilizer
Features
  • Good dimensional stability
  • Rigidity, high
  • High strength
  • Insulation
  • Good creep resistance
  • Thermal Stability
  • Thermal stability, good
  • High hardness
Uses
  • Electrical components
  • Electrical housing
  • Industrial application
  • Insulating material
  • Shell
Processing Method
  • Injection molding
PhysicalDryConditionedUnitTest Method
Density (23°C)1.36--g/cm³ISO 1183
Melt Volume-Flow Rate (MVR) (275°C/5.0 kg)45.0--cm³/10minISO 1133
Molding Shrinkage
     Vertical flow direction 0.40 - 0.45--%
     Flow direction 0.30 - 0.35--%
Water Absorption ISO 62
     Saturated, 23°C 6.7--%ISO 62
     Equilibrium, 23°C, 50% RH 2.1--%ISO 62
Viscosity Number 145--cm³/gISO 307
MechanicalDryConditionedUnitTest Method
Tensile Modulus (23°C)93006200MPaISO 527-2/1
Tensile Stress (Break, 23°C)190110MPaISO 527-2/50
Nominal Tensile Strain at Break (23°C)3.05.0%ISO 527-2/50
Flexural Modulus 1(23°C)80005100MPaISO 178
Flexural Stress 2(23°C)250180MPaISO 178
ImpactDryConditionedUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
     -30°C 10--kJ/m²ISO 179/1eA
     23°C 1325kJ/m²ISO 179/1eA
Charpy Unnotched Impact Strength ISO 179/1eU
     -30°C 75--kJ/m²ISO 179/1eU
     23°C 8595kJ/m²ISO 179/1eU
ThermalDryConditionedUnitTest Method
Heat Deflection Temperature
     0.45 MPa, not annealed 215--°CISO 75-2/B
     1.8 MPa, not annealed 210--°CISO 75-2/A
Melting Temperature (DSC) 3222--°CISO 3146
Linear thermal expansion coefficient ISO 11359-2
     Flow : 23 to 80°C 2.0E-5--cm/cm/°CISO 11359-2
     Lateral : 23 to 80°C 6.0E-5--cm/cm/°CISO 11359-2
ElectricalDryConditionedUnitTest Method
Surface Resistivity 1.0E+131.0E+10ohmsIEC 60093
Volume Resistivity 1.0E+151.0E+12ohms·cmIEC 60093
Dielectric Constant (1 MHz)3.806.80IEC 60250
Dissipation Factor (1 MHz)0.0230.22IEC 60250
Comparative Tracking Index 500--VIEC 60112
FlammabilityDryConditionedUnitTest Method
Flame Rating (1.50 mm)HB--UL 94
InjectionDryUnit
Drying Temperature < 80.0°C
Drying Time 4.0 - 6.0hr
Processing (Melt) Temp 250 - 270°C
Mold Temperature 40.0 - 80.0°C
Injection Rate Moderate-Fast
Injection instructions
Back Pressure: moderate
Note Message
1 .2.0 mm/min
2 .2.0 mm/min
3 .10°C/min
Resin Grade Manufacturer Category Trademark
Nylene® 9543 Custom Resins Group Nylon 612 Nylene®
Aurora PVC AP3000 Series Aurora Plastics, Inc. PVC, Rigid Aurora PVC
EcoVid 80TFH Greener Polymers Inc. PLA EcoVid
Hanwha Total PE F120U HANWHA TOTAL PETROCHEMICALS Co., Ltd. HDPE Hanwha Total PE
Luran® 2580 Styrolution SAN Luran®