Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | AD majoris |
Trademark: | VENYL |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | I1m44w_VENYL-UG100---7821.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
VENYL UG100 - 7821 is a 10 % glass fibre reinforced polyamide 66 intended for Injection moulding. APPLICATIONS VENYL UG100 - 7821 has been developed especially for very demanding applications in automotive industry and electrical parts requiring excellent combination between thermal and mechanical properties. VENYL UG100 - 7821 is available in natural (VENYL UG108) but other colours can be provided on request. |
General Information | |
---|---|
Filler / Reinforcement |
|
Features |
|
Uses |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.21 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | 0.90 to 1.3 | -- | % | |
Water Absorption (Equilibrium, 23°C, 50% RH) | 2.0 | -- | % |
Hardness | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Rockwell Hardness (L-Scale) | 107 | 95 | ASTM D785 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 5000 | 3800 | MPa | ISO 527-2 |
Tensile Stress (Break) | 100 | 70.0 | MPa | ISO 527-2 |
Tensile Strain (Break) | 4.0 | 10 | % | ISO 527-2 |
Flexural Modulus | 4500 | 2300 | MPa | ISO 178 |
Flexural Stress | 160 | 130 | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | 5.0 | 11 | kJ/m² | ISO 179 |
Charpy Unnotched Impact Strength | 20 | 30 | kJ/m² | ISO 179 |
Notched Izod Impact | 70 | 100 | J/m | ISO 180 |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 240 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 220 | -- | °C | ISO 75-2/A |
Melting Temperature (DSC) | 256 | -- | °C | ISO 3146 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | 1.0E+13 | 1.0E+11 | ohms | DIN 53482 |
Volume Resistivity | 1.0E+14 | 1.0E+12 | ohms·cm | DIN 53482 |
Comparative Tracking Index (Solution A) | 600 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating (1.60 mm) | HB | -- | UL 94 | |
Glow Wire Flammability Index (2.00 mm) | 650 | -- | °C | IEC 60695-2-12 |
Oxygen Index | 25 | -- | % | ISO 4589-2 |
Injection | Dry | Unit | |
---|---|---|---|
Rear Temperature | 285 to 300 | °C | |
Middle Temperature | 280 to 295 | °C | |
Front Temperature | 275 to 290 | °C | |
Nozzle Temperature | 265 to 280 | °C | |
Mold Temperature | 90.0 to 120 | °C | |
Injection Pressure | 85.0 to 110 | MPa | |
Injection Rate | Fast | ||
Holding Pressure | 50.0 to 70.0 | MPa | |
Screw L/D Ratio | 15.0:1.0 to 20.0:1.0 |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
POPELEN JHC-371 | Lotte Chemical Corporation | PP Impact Copolymer | POPELEN |
RTP 2301 C | RTP Company | PUR, Unspecified | RTP |
Spartech Polycom SC1-5010 | Spartech Polycom | ABS | Spartech |
Andur 5 DPLM/Curene® 442 | Anderson Development Company | PUR-Ester/TDI | Andur |
Huafon JF-A-5015 | Huafon Group Co., Ltd. | PUR, Unspecified | Huafon |