Category: | PPA , Polyphthalamide |
Manufacturer: | RTP Company |
Trademark: | RTP |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | GVndhC_RTP-4007-TFE-20.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Warning: The status of this material is 'Commercial: Limited Issue' The data for this material has not been recently verified. Please contact RTP Company for current information prior to specifying this grade. -Preliminary Product Data per RTP Co.- |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
RoHS Compliance |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.72 | g/cm³ | ASTM D792 |
Molding Shrinkage - Flow (3.18 mm) | 0.10 | % | ASTM D955 |
Water Absorption (23°C, 24 hr) | 0.20 | % | ASTM D570 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 15900 | MPa | ASTM D638 |
Tensile Strength | 231 | MPa | ASTM D638 |
Tensile Elongation (Break) | 2.0 | % | ASTM D638 |
Flexural Modulus | 14800 | MPa | ASTM D790 |
Flexural Strength | 324 | MPa | ASTM D790 |
Coefficient of Friction (With Metal-Dynamic) | 0.28 | ASTM D1894 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Notched Izod Impact (3.18 mm) | 110 | J/m | ASTM D256 |
Unnotched Izod Impact (3.18 mm) | 850 | J/m | ASTM D4812 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load (1.8 MPa, Unannealed) | 279 | °C | ASTM D648 |
CLTE - Flow | 1.8E-5 | cm/cm/°C | ASTM D696 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity | 1.0E+15 | ohms·cm | ASTM D257 |
Dielectric Strength | 20 | kV/mm | ASTM D149 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | HB | UL 94 |
Additional Information |
---|
Mold Shrinkage, Linear-Flow, ASTM D955, 0.25in.: 2mil/in.Wear Factor, K, ASTM D3702: 20E-10in³/min/ft/lb/hrCoefficient of Friction, Dynamic, ASTM D3702: 0.28The wear factor and coefficient of friction were both tested on a Falex Model No.6 Wear Testing Machine at 50 FPM, 2000 PV, against C1018 steel of hardness 15-25 Rockwell C, 14-17 micro smoothness. |
Injection | Nominal Value | Unit | |
---|---|---|---|
Rear Temperature | 304 - 343 | °C | |
Middle Temperature | 304 - 343 | °C | |
Front Temperature | 304 - 343 | °C | |
Mold Temperature | 93.3 - 149 | °C | |
Injection Pressure | 68.9 - 138 | MPa |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Adell Polyamide AC-10 | Adell Plastics, Inc. | Nylon 66 | Adell Polyamide |
Brush-On® 60 | Smooth-On, Inc | PUR, Unspecified | Brush-On® |
Hifax TYC 773X | LyondellBasell Industries | TPO (POE) | Hifax |
Hyflon® MFA® F1520 | Solvay Specialty Polymers | Perfluoropolymer | Hyflon® MFA® |
Comco PA6G COLOR | Comco Nylon GmbH | Nylon 6 | Comco |