Category: | Nylon 12 , Polyamide 12 |
Manufacturer: | EMS-GRIVORY |
Trademark: | Grilamid® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | A97MUz_Grilamid-L-20-LF-grey.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Grilamid® L 20 LF grey is a Polyamide 12 (Nylon 12) material. It is available in Africa & Middle East, Asia Pacific, Europe, Latin America, or North America for extrusion or injection molding. Important attributes of Grilamid® L 20 LF grey are:
Typical applications include:
|
General Information | |
---|---|
Additive |
|
Features |
|
Uses |
|
RoHS Compliance |
|
Appearance |
|
Forms |
|
Processing Method |
|
Multi-Point Data |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.08 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 0.60 | -- | % | |
Flow | 0.40 | -- | % | |
Water Absorption | ISO 62 | |||
Saturation, 23°C | 1.5 | -- | % | |
Equilibrium, 23°C, 50% RH | 0.70 | -- | % |
Hardness | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Shore Hardness (Shore D, 15 sec) | -- | 72 | ISO 868 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 2200 | 2000 | MPa | ISO 527-2 |
Tensile Stress | ISO 527-2 | |||
Yield | 50.0 | 45.0 | MPa | |
Break | 40.0 | 40.0 | MPa | |
Tensile Strain (Yield) | 10 | 12 | % | ISO 527-2 |
Nominal Tensile Strain at Break | 40 | 40 | % | ISO 527-2 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | -- | 3.0 | kJ/m² | |
23°C | -- | 4.0 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | No Break | No Break | ||
23°C | No Break | No Break |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 140 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 65.0 | -- | °C | ISO 75-2/A |
Continuous Use Temperature | Internal Method | |||
-- 1 | 90.0 to 110 | -- | °C | |
-- 2 | 150 | -- | °C | |
Melting Temperature 3 | 178 | -- | °C | ISO 11357-3 |
CLTE | ISO 11359-2 | |||
Flow | 8.0E-5 | -- | cm/cm/°C | |
Transverse | 1.3E-4 | -- | cm/cm/°C |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | -- | 1.0E+12 | ohms | IEC 60093 |
Volume Resistivity | -- | 1.0E+13 | ohms·cm | IEC 60093 |
Electric Strength | -- | 21 | kV/mm | IEC 60243-1 |
Comparative Tracking Index | -- | 225 | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flammability Classification (0.800 mm) | HB | -- | IEC 60695-11-10, -20 |
Additional Information | Dry | Conditioned | Test Method | |
---|---|---|---|---|
ISO Type | PA12, MHZ, 18-020, CD12 | -- | ISO 1874 |
Note Message | |
---|---|
1 . | Long Term |
2 . | Short Term |
3 . | 10°C/min |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Sunny® ASA EB100 | Guangdong Shunde Shunyan New Material Co., Ltd. | ASA | Sunny® |
TOTAL Polystyrene FT 875 (AS) | TOTAL Refining & Chemicals | PS (HIPS) | TOTAL Polystyrene |
APEX® 3201-70NT | Teknor Apex Company | PVC, Flexible | APEX® |
Electrafil® J-1/CF/30 | Techmer Engineered Solutions | Nylon 66 | Electrafil® |
Generic PUR-Ether/TDI | Generic | PUR-Ether/TDI | Generic |