| Physical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Density | 1.61 | g/cm³ | ISO 1183 |
| Molding Shrinkage 1 | ISO 2577 | ||
| Transverse flow | 1.1 | % | ISO 2577 |
| Flow | 0.30 | % | ISO 2577 |
| Water Absorption | ISO 62 | ||
| 23°C, 24 hr | 0.15 | % | ISO 62 |
| Saturated, 23°C | 0.40 | % | ISO 62 |
| Viscosity Number (Reduced Viscosity) | 60.0 | ml/g | ISO 1628 |
| Hardness | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Ball Indentation Hardness 2 | 240 | MPa | ISO 2039-1 |
| Mechanical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Tensile Modulus | 10200 | MPa | ISO 527-2/1 |
| Tensile Stress (Break) | 150 | MPa | ISO 527-2/5 |
| Tensile Strain (Break) | 2.1 | % | ISO 527-2/5 |
| Impact | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/1eA | ||
| -30°C | 8.0 | kJ/m² | ISO 179/1eA |
| 23°C | 8.0 | kJ/m² | ISO 179/1eA |
| Charpy Unnotched Impact Strength | ISO 179/1eU | ||
| -30°C | 29 | kJ/m² | ISO 179/1eU |
| 23°C | 30 | kJ/m² | ISO 179/1eU |
| Thermal | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Heat Deflection Temperature | |||
| 1.8 MPa, not annealed | 200 | °C | ISO 75-2/A |
| 8.0 MPa, not annealed | 121 | °C | ISO 75-2/C |
| Vicat Softening Temperature | 230 | °C | ISO 306/B50 |
| Melting Temperature 3 | 240 | °C | ISO 11357-3 |
| CLTE - Flow (23 to 80°C) | 2.0E-5 | cm/cm/°C | ISO 11359-2 |
| Electrical | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Surface Resistivity | > 1.0E+14 | ohms | IEC 60093 |
| Volume Resistivity | > 1.0E+16 | ohms·cm | IEC 60093 |
| Dielectric Strength (1.00 mm) | 31 | kV/mm | IEC 60243-1 |
| Relative Permittivity | IEC 60250 | ||
| 100 Hz | 4.30 | IEC 60250 | |
| 1 MHz | 4.00 | IEC 60250 | |
| Comparative Tracking Index (Solution A) | 250 | V | IEC 60112 |
| Flammability | Nominal Value | Unit | Test Method |
|---|---|---|---|
| Flame Rating (0.8 mm) | HB | UL 94 | |
| Glow Wire Flammability Index (2.0 mm) | 750 | °C | IEC 60695-2-12 |
| Note Message | |
|---|---|
| 1 . | 275°C / WZ 135 bzw. 100°C, 600 bar |
| 2 . | 358 N |
| 3 . | 10°C/min |
| Resin Grade | Manufacturer | Category | Trademark |
|---|---|---|---|
| NILENE® P20 K65B | Taro Plast S.p.A. | PP Homopolymer | NILENE® |
| Nylfor® A2 MF/40 NATURALE | SO.F.TER. SPA | Nylon 66 | Nylfor® |
| ColorRx® PA-2000NB | LTL Color Compounders, Inc. | PC+ABS | ColorRx® |
| Kingfa PA6-MG30 | Kingfa | Nylon 6 | Kingfa |
| LubriOne™ AS-000/15T | PolyOne Corporation | ABS | LubriOne™ |