Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | CP-Polymer-Technik GmbH & Co. KG |
Trademark: | WELLAMID Nylon |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | 8rKK5G_WELLAMID-Nylon-6000-MF-30-HWCP.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
WELLAMID Nylon 6000 MF 30 HWCP is a Polyamide 6 (Nylon 6) material filled with 30% milled glass fiber. It is available in Europe. Important attributes of WELLAMID Nylon 6000 MF 30 HWCP are:
|
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.32 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow : 4.00 mm | 0.70 | -- | % | |
Flow : 4.00 mm | 0.50 | -- | % | |
Water Absorption (Equilibrium, 23°C, 50% RH) | 1.8 to 2.3 | -- | % | ISO 62 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 7500 | 5000 | MPa | ISO 527-2 |
Tensile Stress (Break) | 130 | 80.0 | MPa | ISO 527-2/5 |
Tensile Strain (Break) | 3.0 | 6.0 | % | ISO 527-2/5 |
Flexural Modulus | 6100 | -- | MPa | DIN 52457 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength (23°C) | 10 | 22 | kJ/m² | ISO 179 |
Charpy Unnotched Impact Strength (23°C) | 35 | 70 | kJ/m² | ISO 179 |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 200 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 140 | -- | °C | ISO 75-2/A |
Vicat Softening Temperature | 200 | -- | °C | ISO 306/B50 |
Melting Temperature | 215 | -- | °C | |
CLTE - Flow (23 to 80°C) | 3.0E-5 | -- | cm/cm/°C | DIN 53752 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | 1.0E+12 | 1.0E+10 | ohms | IEC 60093 |
Volume Resistivity | 1.0E+15 | 1.0E+12 | ohms·cm | IEC 60093 |
Electric Strength | 40 | 35 | kV/mm | IEC 60243-1 |
Relative Permittivity (1 MHz) | 4.00 | 7.00 | IEC 60250 | |
Dissipation Factor (1 MHz) | 0.022 | 0.20 | IEC 60250 | |
Comparative Tracking Index | 550 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating | UL 94 | |||
1.60 mm | HB | -- | ||
3.20 mm | HB | -- |
Injection | Dry | Unit | |
---|---|---|---|
Processing (Melt) Temp | 250 to 280 | °C | |
Mold Temperature | 60.0 to 90.0 | °C | |
Injection Rate | Moderate-Fast |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Borealis PP ZP961 | Borealis AG | TPO | Borealis PP |
Formolene® 2306N | Formosa Plastics Corporation, U.S.A. | PP Impact Copolymer | Formolene® |
Jampilen HP561R | Jam Polypropylene Company | PP Homopolymer | Jampilen |
Sylvin 6185-80 Grey 9166 | Sylvin Technologies Incorporated | PVC, Unspecified | Sylvin |
EPAMOULD 660D12G20 | Epaflex Polyurethanes S.R.L. | TPU, Unspecified | EPAMOULD |